Desa FSVYD18P Stove User Manual


 
7
104462
OWNER’S MANUAL
WARNING: Never install the
heater
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture,
clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater
in high traffic areas
in windy or drafty areas
INSTALLATION
WARNING: A qualified ser-
vice person must install heater.
Follow all local codes.
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply
is not propane/LP gas, do not install heater.
Call dealer where you bought heater for
proper type heater.
IMPORTANT:
Vent-free heaters add mois-
ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation, pages 4 through 6.
CLEARANCES TO
COMBUSTIBLES
(Vent-Free Operation Only)
WARNING: Maintain the mini-
mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining side
and back walls.
Carefully follow the instructions below. This
stove is a freestanding unit designed to set
directly on the floor.
IMPORTANT:
You
must maintain minimum wall and ceiling
clearances during installation. The mini-
mum clearances are shown in Figure 4.
Measure from outermost point of stove top.
Minimum Wall and Ceiling
Clearances (see Figure 4)
A. Clearances from outermost point of
stove top to any combustible side wall
should not be less than 12 inches.
B. Clearances from outermost point of
stove top to any combustible back wall
should not be less than 6 inches (In-
cludes Corner Installations).
C. Clearances from the stove top to the
ceiling should not be less than 48
inches.
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
systems circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May Vary Depending on
Model)
Front View
Top View
Side View
Front of
Stove Unit
Continued
12"
Minimum
12"
Minimum
48"
Minimum
Ceiling
Side Wall Side Wall
Back Wall
Side Wall Side Wall
12
"
Minimum
12
"
Minimum
6
"
Minimum
6"
Minimum
48"
Minimum
Ceiling
Floor
Back Wall
Corner
Wall
Wall
6
"
Minimum
6
"
Minimum