Desa FPVF33PRA Indoor Fireplace User Manual


 
www.desatech.com
113109-01C26
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1.
Control knob not fully pressed in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Pilot ame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
5. Thermocouple connection
loose at control valve
6. Thermocouple damaged
7. Control valve damaged
1. Inlet gas pressure is too low
2. Burner orice(s) clogged
3. Thermopile leads disconnected
or improperly connected
4. Burner will not come on in
remote position
1. Manifold pressure is too low
2. Burner orice(s) clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Not enough air
2. Gas regulator defective
3. Residues from manufacturing
processes and logs curing
REMEDY
1. Press in control knob fully
2.
After ODS/pilot lights, keep con-
trol knob pressed in 30 seconds
3. Fully open equipment shutoff
valve
4. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 24) or replace ODS/pilot
assembly
5. Hand tighten until snug, then
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see Cleaning
and Maintenance, page 24) or
replace burner orice(s)
3. Reconnect leads (see Wiring
Diagram, page 29)
4. Replace battery in transmitter
and receiver
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner(s) (see Cleaning
and Maintenance, page 24) or
replace burner orice(s)
1. Clean burner (see Cleaning
and Maintenance, page 24)
or replace burner orice(s)
2. Replace damaged burner
3. Replace gas regulator
1. Check burner for dirt and
debris. If found, clean burner
(see Cleaning and Mainte-
nance, page 24)
2. Replace gas control
3. Problem will stop after a few
hours of operation
OBSERVED PROBLEM
ODS/pilot lights but flame
goes out when control knob is
released
Burner does not light after
ODS/pilot is lit
Delayed ignition of one or both
burners
Burner backring during com-
bustion
Slight smoke or odor during
initial operation