Desa E32LB Indoor Fireplace User Manual


 
www.desatech.com
111076-01F4
INSTALLATION CLEARANCES
Minimum clearances to combustible construction are:
Top, Back and Sides of Recessed
Cabinet . . . . . . . . . . . . . . . . . . . . .0" Min.
Drywall to Sides of Front Face . . .0" Min.
Framing at Nailing Flanges . . . . . .0" Min.
Ceiling to Opening . . . . . . . . . . . .36" Min.
Facing Material May
Be Noncombustible
Wall Treatments or
Combustible Wood
Combustible Wood
Mantels and Trims
May Extend Above
Profile Shown when
Maintained within
30° Parameter
Shown
Framed
Material
Top of Cabinet
Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening
30°
16
5
/
8
"
Ref.
9
5
/
8
" Ref.
12" Ref.
13
3
/
4
"
4
1
/
2
"
1
1
/
2
"
1
3
/
4
"
10
1
/
2
" Min.
10
1
/
2
"
Figure 3 - Mantel Clearances
Top View of Fireplace
Safe Zone
5"
3"
30°
1
3
/
4
" Max.
Minimum 10" from
Perpendicular Side Wall
Edge of Firebox
Opening
Combustible
MaterialMust
Not Overlap
Front Face
Figure 4 - Mantel Side Clearances
INSTALLATION
Continued
Floor . . . . . . . . . . . . . . . . . . . . . . .0" Min.
Front . . . . . . . . . . . . . . . . . . . . . .36" Min.
Perpendicular Side Wall . . . . . . .10" Min.
Mantel Clearances
For mantel clearances see Figures 3 and 4.