Desa E32LB Indoor Fireplace User Manual


 
www.desatech.com
111076-01F22
MAINTENANCE
Continued
CLEANING VIEWING SCREEN
Clean viewing screen with an alcohol based,
nonabrasive, residue free cleaner (premoist-
ened hand wipes are ideal). Do not use glass
cleaners with ammonium, abrasive scrubs or
degreaser solvents of any kind.
ACCESSING IMAGING UNIT FOR
REPLACEMENT
The imaging unit can be removed from inside
the rebox for servicing or replacement:
1. Follow steps under Accessing Imaging
Unit, on page 18.
2. Remove 4 hex screws on lower louver
panel and detach louver assembly from
front face (see Figure 38).
3. Rotate top edge of lower frame rail inward
and lift upward until locking tabs detach
from front face (see Figure 38).
4. Slide entire imaging unit forward and lift
out through front opening (see Figure 39,
page 23).
Note: An additional 3 feet of harness is tucked
behind imager to permit removal without dis-
connecting any control wiring.
3. If upper back cabinet ribbons need re-
placing, remove 4 Phillips screws holding
corresponding bottom and top hanger
brackets (see Figure 37, page 21).
4. Remove any loose or damaged ribbon
material.
5. Cut an 18” strip of reective ribbon and
position top end about an inch above top
bracket position (see Figure 37, page 21).
Note: Ribbon material should be ap-
plied with reective side up, should not
be twisted or tangled, and should hang
slightly loose to allow free movement.
If additional parts are required, see Re-
placement Parts, page 23.
6. Replace top hanger bracket using 2 Phil-
lips screws removed in step 2 and tighten
until reective ribbon is held in place.
7. Replace bottom hanger bracket using 2
remaining Phillips screws to secure lower
end of reective ribbon.
8. If replacing reective ribbons located in
base, remove screws and washers at
damaged ends of ribbon.
9. Cut a 9" long strip of ribbon and apply across
each ribbon support bracket with shiny side
facing up (see Figure 37, page 21).
10. Secure ribbon to brackets by replacing
each washer at end of the ribbon and re-
threading screws through the ribbon into
each hole located on support brackets.
11. If replacing top reective ribbons on base
cover, cut a 3" section of ribbon and split
down the middle. With shiny side up, attach
with cellophane tape into rear edge of base
cover opening (see Figure 37, page 21).
12. Readjust ame pennants (if removed). See
Servicing Flame Pennants, page 19.
13. Reassemble imager. See Accessing
Imaging Unit, page 18.
14. Center log bed over opening between
viewing panel screen and grate.
15. Cover remaining hearth area with 1/4" of
lava rock (provided), if desired.
Figure 38 - Removing Lower Louver
Panel and Frame Rail
Lower Panel
Lower
Frame
Rail
Lower Frame
Rail
Locking Tab