Desa CRL3124P/N Electric Heater User Manual


 
www.desatech.com 111160-01C
4
4. If you smell gas
shut off gas supply
do not try to light any appliance
do not touch any electrical switch; do not
use any phone in your building
immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
if you cannot reach your gas supplier, call
the fire department
5. This heater shall not be installed in a bedroom
or bathroom unless installed as a vented ap-
pliance (Variable Manually-Controlled Mod-
els Only) (see Installing Damper Clamp Ac-
cessory for Vented Operation, page 11).
6. Before installing in a solid fuel burning fireplace,
the chimney flue and firebox must be cleaned of
soot, creosote, ashes and loose paint by a quali-
fied chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue may cre-
ate and distribute soot within the house. In-
spect chimney flue for damage. If damaged,
repair flue and firebox before operating heater.
7. Do not burn solid-fuel in a masonry or UL127
factory-built fireplace in which a vent-free
room heater is installed.
8. If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside fire-
place will cause glass to burst. Make sure there
are no obstructions across openings of fireplace.
9.
This log heater is designed to be smokeless. If
logs ever appear to smoke, turn off heater and call
a qualified service person.
Note:
During initial
operation, slight smoking could occur due to log
curing and heater burning manufacturing residues.
10. To prevent the creation of soot, follow the in-
structions in Cleaning and Maintenance, pages
24 and 25.
11. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
12. This heater needs fresh, outside air ventila-
tion to run properly. This heater has an Oxy-
gen Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater if not
enough fresh air is available. See Air for Com-
bustion and Ventilation, pages 5 through 7. If
heater keeps shutting off, see Troubleshoot-
ing, pages 26 through 28.
13. Do not run heater
• where flammable liquids or vapors are used
or stored
under dusty conditions
SAFETY INFORMATION
Continued
14. Do not use this heater to cook food or burn
paper or other objects.
15. Do not use heater if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the room heater and
to replace any part of the control system and
any gas control which has been under water.
16. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dime-
sized or larger).
17. Turn heater off and let cool before servicing.
Only a qualified service person should ser-
vice and repair heater.
18. Operating heater above elevations of 4,500
feet could cause pilot outage.
19. Provide adequate clearances around air
openings.
PRODUCT
IDENTIFICATION
Figure 1 - Vent-Free Gas Log Heater -
Dual Burner (Logs May Vary by Model -
Smoky Mountain Oak Model Shown)
Figure 2 - Vent-Free Gas Log Heater -
Single Burner (Logs May Vary by Model -
Seasonal Oak Model Shown)
Middle Log
Front
Log
Control
Knob
Back Log
Base
Grate
Burner
Piezo
Ignitor
Crossover Log
Front Log
Control Knob
Back Log
Burner
Piezo
Ignitor
Crossover Log