Desa CRL3124P/N Electric Heater User Manual


 
www.desatech.com
111160-01C 11
Minimum
Noncombustible
Material
8"
Min.
12" 15" 18"
All minimum
distances are
in inches
Log Set
18", 24",
30" Mod
e
20"
2
1
/2
"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050,
GA6052)
Top of
Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
INSTALLATION
Continued
Figure 8 - Minimum Mantel Clearances
When Using Hood
(GA6050,
GA6052, and
GA6053)
All
Models
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
operate the logs only with the
flue damper open
raise the mantel to an accept-
able height
remove the mantel
14"
Min.
Combustible
Material
Noncombustible
Material
Hearth
5"
Min.
Combustible
Material
Figure 10 - Minimum Fireplace
Clearances Above Combustible Flooring
Figure 9 - Minimum Fireplace Clearances
if Installed at Floor Level
FLOOR CLEARANCES
A. If installing appliance on the floor level, you
must maintain the minimum distance of 14"
to combustibles (see Figure 9).
B. If combustible materials are less than 14" to the
fireplace, you must install appliance at least 5"
above the combustible flooring (see Figure 10).
INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION
Note:
When used as a vented heater, appliance
must be installed only in a solid-fuel burning fire-
place with a working flue and constructed of non-
combustible material.
If your heater is a manually controlled model, you
may use this heater as a vented product. There are
three reasons for operating your heater in the
vented mode.
1. The fireplace does not meet the clearance to com-
bustibles requirements for vent-free operation.
2. State or local codes do not permit vent-free
operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you
must permanently open chimney flue damper. You
must install the damper clamp accessory (to or-
der, see Accessories, page 43). This will insure
vented operation (see Figure 11). The damper
clamp will keep damper open. Installation instruc-
tions are included with clamp accessory.
Figure 11 - Attaching Damper Clamp
Manufactured
Fireplace
Masonry
Fireplace
Damper
Damper
Clamp
Damper
Damper
Clamp
Damper