Desa CLD3018NA 24" Water Heater User Manual


 
107068
For more information, visit www.desatech.com
For more information, visit www.desatech.com
9
9
INSTALLATION
Mantel Clearances
Floor Clearances
INSTALLATION
Continued
MANTEL CLEARANCES
In addition to meeting noncombustible material clearances, you
must also meet required clearances between fireplace opening and
mantel shelf. If you do not meet the clearances listed below, you will
need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel shelf and top of
fireplace opening, a hood is not required (see Figure 6).
Determining Minimum Mantel Clearance when
Using a Hood
If minimum clearances in Figure 6 are not met, you must have a hood.
When using a hood there are still certain minimum mantel clearances
required. Follow minimum clearances shown in Figure 7 when using
a hood.
NOTICE: If your installation does not meet the mini-
mum clearances shown, you must do one of the
following:
operate the logs only with the flue damper open
raise the mantel to an acceptable height
remove the mantel
FLOOR CLEARANCES
A. If installing appliance on the floor level, you must maintain
the minimum distance of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14" to the fireplace, you
must install appliance at least 5" above the combustible floor-
ing (see Figure 9).
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard.
Follow all minimum clearances shown in this manual.
Figure 6 - Minimum Mantel Clearances Without Using Hood
14"
Min.
Combustible
Material
Noncombustible Material
Hearth
5"
Min.
Combustible
Material
Figure 9 - Minimum Fireplace
Clearances Above
Combustible Flooring
Figure 7 - Minimum Mantel Clearances When Using Hood
Figure 8 - Minimum Fireplace
Clearances If Installed at Floor
Level
Minimum Non-
Combustible
Material
8"
Min.
12" 15" 18"
All minimum
distances are
in inches
Log Set
18" and 24"
Models
20"
2
1
/2
"
6"
8"
10"
12"
Distances to
Underside of
Mantel
Hood
(GA6050, GA6052)
Top of Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
Minimum Non-
Combustible
Material
Minimum Non-
Combustible
Material Height
Distances to
Underside of
Mantel
Top of Fireplace
Opening
Underside of
Mantel Shelf
Mantel Shelf
12"
8"
(A)
18"
8"
20"
14"
22"
17"
24"
20"
All minimum
distances are
in inches
Log Set
24" Model
18" Model
2
1
/2
"
6"
8"
10"
(GA6050, GA6052,
or GA6053)