www.desatech.com
111161-01H 25
1.
Control knob not fully pressed
in
2. Control knob not pressed in
long enough
3. Equipment shutoff valve not
fully open
4. Pilot ame not touching ther-
mocouple, which allows ther-
mocouple to cool, causing
pilot flame to go out. This
problem could be caused by
one or both of the following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
5. Thermocouple connection
loose at control valve
6. Thermocouple damaged
7. Control valve damaged
1. Burner orice clogged
2. Inlet gas pressure is too low
3. Thermopile leads disconnect-
ed or improperly connected
4. Burners will not come on in
remote position
1. Manifold pressure is too low
2. Burner orice clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds
3. Fully open equipment shutoff
valve
4. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance,
page 23) or replace ODS/pilot
assembly
5. Hand tighten until snug, then
tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
1. Clean burner (see Cleaning
and Maintenance, page 23)
or replace burner orice
2. Contact local natural or pro-
pane/LP gas company
3. Reconnect leads (see Wiring
Diagram, page 32)
4. Replace battery in transmitter
and receiver
1. Contact local natural or pro-
pane/LP gas company
2. Clean burner (see Cleaning
and Maintenance, page 23)
or replace burner orice
1. Clean burner (see Cleaning
and Maintenance, page 23)
or replace burner orice
2. Replace damaged burner
3. Replace gas control
ODS/pilot lights but flame
goes out when control knob is
released
Burner does light after ODS/
pilot is lit
Delayed ignition burner
Burner backring during com-
bustion
TROUbLESHOOTING