Desa CGP10R Electric Heater User Manual


 
14
103548
GAS RESIDENTIAL HEATERS
When gas pressure is too low
• pilot will not stay lit
• burner(s) will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
TROUBLESHOOTING
Continued
TECHNICAL
SERVICE
You may have further questions about in-
stallation, operation, or Trouble Shooting.
If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
Operating heater where im-
purities in air exist may create odors. Clean-
ing supplies, paint, paint remover, cigarette
smoke, cements and glues, new carpet or
textiles, etc., create fumes. These fumes
may mix with combustion air and create
odors.
OBSERVEDPROBLEM
Heater produces unwanted odors
POSSIBLE CAUSE
1. Heater burning vapors from paint, hair
spray, glues, etc. (See
IMPORTANT
statement above
2. Low fuel supply
3. Gas leak. See Warning statement at top
of page
REMEDY
1. Ventilate room. Stop using odor-causing
products while heater is running
2. Refill supply tank
3. Locate and correct all leaks (see
Checking Gas Connections, page 9)
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Refer to Air for Combustion and
Ventilation requirements (page 3)
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 15)
Gas odor even when control knob is in OFF
position
1. Gas leak. See Warning statement at top
of page
2. Control valve defective
1. Locate and correct all leaks (see
Checking Gas Connections, page 9)
2. Replace control valve
Gas odor during combustion
1. Foreign matter between control valve
and burner
2. Gas leak. See Warning statement at top
of page
1. Take apart gas tubing and remove
foreign matter
2. Locate and correct all leaks (see
Checking Gas Connections, page 9)
Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air
1. Refer to Air for Combustion and
Ventilation requirements (page 3)
SERVICE HINTS
When gas quality is bad
• pilot will not stay lit
• burner(s) will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.
Heater shuts off in use (ODS operates)