Desa CGN10TLA Electric Heater User Manual


 
11
104267
OWNER’S MANUAL
Figure 15 - Control Knob In The OFF
Position
LIGHTING
INSTRUCTIONS
1. STOP! Read the safety informa-
tion, page 10.
2. Make sure equipment shutoff valve
is fully open.
3. Turn control knob clock-
wise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out
any gas. Then smell for gas, includ-
ing near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation on page 10. If you don’t
smell gas, go to the next step.
5. Turn control knob counterclock-
wise
C-clockwise
to the PILOT posi-
tion. Press in control knob for five
(5) seconds (see Figure 15).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed
in for 30 seconds. This will allow
air to bleed from the gas system.
6. With control knob pressed in, push
down and release ignitor button.
This will light pilot. The pilot is at-
tached to the front of burner. The
pilot can be seen through the glass
panel. If needed, keep pressing ig-
nitor button until pilot lights.
Note:
If pilot does not stay lit, re-
fer to Troubleshooting, pages 13
through 15. Also contact a qualified
service person or gas supplier for
repairs. Until repairs are made,
light pilot with match. To light pi-
lot with match, see Manual Light-
ing Procedure, column 3.
7. Keep control knob pressed in for
30 seconds after lighting pilot. Af-
ter 30 seconds, release control
knob.
If control knob does not pop up
when released, contact a quali-
fied service person or gas sup-
plier for repairs.
OPERATING
HEATER
Continued
IGNITOR
PILOT
LO
OFF
HI
Control
Knob
Ignitor
Button
Note:
If pilot goes out, repeat steps
3 through 7. This heater has a safety
interlock system. Wait one (1) minute
before lighting pilot again.
8. Turn control knob counterclockwise
C-clockwise
to desired heating level. The
main burner should light. Set control
knob to any heat level between HI
and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Figure 16 - Pilot
Pilot Burner
Ignitor Electrode
Thermocouple
TO TURN OFF GAS TO
APPLIANCE
1. Remove front panel (see Figure 10,
page 8).
2. Follow steps 1 through 5 under Light-
ing Instructions, column 1.
3. With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.
4. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Follow
step 8 under Lighting Instructions,
column 2.
5. Replace front panel.
Shutting Off Heater
1. Turn control knob clockwise
Clockwise
to the OFF position.
2. Turn off all electric power to the ap-
pliance if service is to be performed.
Shutting Off Burner Only (pilot
stays lit)
Turn control knob clockwise
Clockwise
to
the PILOT position.
THERMOSTAT
CONTROL
OPERATION
The thermostatic control used on these
models differs from standard thermo-
stats. Standard thermostats simply turn
on and off the burner. The thermostat
used on this heater senses the room tem-
perature. The thermostat adjusts the
amount of gas flow to the burner. This
increases or decreases the burner flame
height. At times the room may exceed the
set temperature. If so, the burner will
shut off. The burner will cycle back on
when room temperature drops below the
set temperature. The control knob can be
set to any heat level between HI and LO.
Note:
The thermostat sensing bulb mea-
sures the temperature of air near the
heater cabinet. This may not always agree
with room temperature (depending on
housing construction, installation loca-
tion, room size, open air temperatures,
etc.). Frequent use of your heater will let
you determine your own comfort levels.
MANUAL LIGHTING
PROCEDURE