Desa CD36M(-1)(-2) Indoor Fireplace User Manual


 
- 13 - For more information, visit www.desatech.com
Install the identification label enclosed with the
gas valve regulator to the valve body where it can
easily be seen (see figure 23).
FACE EXTENSION (FOR MODEL CD32M ONLY)
Model CD32M comes equipped with a front face extension.
The front face extension would add 3- ½” to the width and ¾”
to the height of the fireplace face.
To install the face extension:
Remove the existing screws from front face assembly
as shown in figure 24.
Align holes on top face extension (figure A) with
holes on the top side of the front face assembly and
secure with screws previously removed (follow this
step to install left and right face extension).
Secure top face extension with left and right face
extensions with two sheet metal screws (figure B).
WARNING: The conversion kit must be installed by
a
qualified service technician in accordance with the
manufacturers instructions and all applicable codes an
d
requirements of the authority having jurisdiction. If an
y
information in these instructions is not followed correctly,
a fire, explosion or production of carbon monoxide ma
y
result causing property damage, personal injury or loss o
f
life. The qualified service technician is responsible for the
proper installation of this conversion kit.
FIGURE A
FIGURE B
Figure 24 FRONT FACE EXTENSION
Figure 23 GAS CONTROL VALVE CONVERSION
WARNING: Never use an open flame to chec
k
for a leak. Apply commercial leak test solution to all
gas joints. Bubbles forming show a leak. Correct all
leaks at once.
WARNING: Test all gas piping and connections
for leaks after installing or servicing. Correct leaks a
t
once.