Desa CCL3930PTB/NTB Electric Heater User Manual


 
www.desatech.com
113097-01E10

You must have noncombustible material(s) above
the replace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2 inch thick. With sheet metal, you must have
noncombustible material behind it. Noncombus-
tible material must extend at least 8" up (for all
models). If noncombustible material is less than
12", you must install the replace hood accessory
(24" and 30" models only). Even if noncombus-
tible material is more than 12", you may need the
hood accessory to deect heat away from your
mantel shelf. See Figure 5 and 6 and Figure 7 on
page 11 for minimum clearances.

In addition to meeting noncombustible material
clearances, you must also meet required clearances
between replace opening and mantel shelf. If
you do not meet the clearances in Figure 6 you
will need a hood.

If you meet minimum clearance between mantel
shelf and top of replace opening, a hood is not
required (see Figure 6).


If minimum clearances in Figure 6 are not met, you
must have a hood. When using a hood there are
still certain minimum mantel clearances required.
Follow minimum clearances shown in Figure 7,
page 11 when using hood.
  
-

    
     
-


Follow all minimum clearances

INSTALLATION
Continued
 
Material Safe Installation

12" or more Noncombustible material
okay.
Between 8" 24", 30" or 36" Models:
and 12" Install replace hood
accessory (GA6050,
GA6052 or GA6053 see
Accessories, page 38).
18" Model: Noncombus-
tible material okay.
Less than 8" Noncombustible material
must be extended to at
least 8". See Between 8"
and 12", above. If you
cannot extend material,
you must operate heater
with ue damper open.
IMPORTANT: If you cannot meet these minimum
clearances, you must operate heater with chimney
ue damper open. Go to Installing Damper Clamp
Accessory for Vented Operation, page 11.
Heat Resistant
Material
(A)
Figure 5 - Heat Resistant Material (Slate,
Marble, Tile, etc.) Above Fireplace
Figure 6 - Minimum Mantel Clearances
Without Using Hood
Minimum
Noncombustible
Material
Minimum
Noncombustible
Material Height
Distances to
Underside of
Mantel
Top of Fireplace
Opening
Underside
of Mantel
Shelf
Mantel Shelf
12"
8"
(A)
18"
8"
20"
14"
22"
17"
24"
20"
All minimum
distances
are in inches
Log Set
24"/30"
Models
18" Model
2
1
/2
"
6"
8"
10"