WARNING ICON G 001
WARNING
Never install the heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are
less than 36 inches from the front, top, or sides of the heater
• in high traffic areas
• in windy or drafty areas
INSTALLING
NOTICE
A qualified service person must install heater. Follow all local codes.
WARNING ICON G001
CAUTION
This heater creates warm air currents. These currents move heat
to wall surfaces next to heater. Installing heater next to vinyl or
cloth wall coverings or operating heater where impurities in the air
(such as tobacco smoke) exist, may discolor walls.
CHECK GAS TYPE
Use only propane gas. If your gas supply is not propane, do not install heater. Call
dealer where you bought heater for proper type heater.
IMPORTANT:
Vent-free heaters add moisture to the air. Although this is benefi-
cial, installing heater in rooms without enough ventilation air may cause mildew
to form from too much moisture. See Air for Combustion and Ventilation, pages 5
through 7.
NOTICE
State or local codes may only allow operation of this appliance in a
vented configuration. Check your state or local codes.
CLEARANCES TO COMBUSTIBLES (Vent-Free Operation Only)
WARNING ICON G 001
WARNING
Maintain the minimum clearances. If you can, provide greater clear-
ances from floor, ceiling, and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding unit designed
to set directly on the floor.
IMPORTANT: You must maintain minimum wall and
ceiling clearances during installation. The minimum clearances are shown in
Figure 4, page 9. Measure from outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from outermost point of stove top to any combustible side wall
should not be less than 12 inches.
B. Clearances from outermost point of stove top to any combustible back wall
should not be less than 6 inches (Includes Corner Installations).
C. Clearances from the stove top to the ceiling should not be less than 48 inches.