OPERATING
HEATER
Continued
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
1. Press in and turn control knob clockwise
Clockwise
to the HIGH position.
2. Turn the control knob clockwise
Clockwise
to the PILOT position.
3. Press in control knob and turn clockwise
Clockwise
to the OFF Position.
Shutting Off Burners Only (pilot stays lit)
1. Turn the control knob clockwise
Clockwise
to the HIGH position.
2. Press in and turn control knob clockwise
Clockwise
to the PILOT position.
MANUAL LIGHTING PROCEDURE
1. Follow steps 1 through 5 under Lighting Instructions, pages 19 and 20.
2. Pilot is located inside stove cavity attached to burner. Lift off top grate to allow
access to pilot.
3. Depress control knob and light pilot with match.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
5. Place top grate back into position. Now follow step 8, page 20.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 24 shows a correct pilot flame pattern. Figure 25 shows an incorrect pilot flame
pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the
thermocouple to cool. When the thermocouple cools, the heater will shut down.
Thermocouple
Pilot Burner
Figure 24 - Correct Pilot
Flame Pattern
Pilot Burner
Thermocouple
Figure 25 - Incorrect Pilot
Flame Pattern
If pilot flame pattern is incorrect, as shown in Figure 25
turn heater off (see To Turn Off Gas to Appliance, above)
see Troubleshooting, pages 22 through 25