Desa 106040-02 Electric Heater User Manual


 
3
105822
INSTALLATION INSTRUCTIONS
HI
LO
O
F
F
P
I
L
O
T
O
N
GAS CONTROL VALVE
CONVERSION
Convert the gas control valve by swapping
out the valve regulator portion of the gas
valve.
1. Using a TORX T20 or slotted screw-
driver, remove and discard the three
mounting screws, pressure regulator
tower, and diaphragm/spring compo-
nents (see Figure 6).
2. Insure that the rubber gasket is prop-
erly positioned on the new pressure
regulator assembly. Install the new
pressure regulator assembly to the valve
using the new mounting screws sup-
plied with the kit. Tighten screws se-
curely (approximately 25in-lbs.) (see
Figure 7).
3. Install the identification label enclosed
with the gas valve regulator to the valve
body where it can easily be seen (see
Figure 7).
CONVERSION LABELING
AND PLACEMENT
1. Apply the English and French conver-
sion labels over the top of the existing
certification labels (see Figure 8). Ex-
isting certification labels are located on
the lighting instruction plate inside the
gas valve compartment area. With per-
manent ink, print the previous model
number on the label in the space pro-
vided (see Figure 9).
2. After filling in the data required on the
conversion information label, affix it to
the floor of the appliance where it is
easily seen when the bottom louver
panel is opened (see Figure 10).
Figure 6 - Removing Mounting Screws,
Pressure Regulator Tower, and
Diaphragm/Spring Components
Figure 7 - Installing Pressure Regulator
Assembly
Mounting Screws
Rubber Gasket
Identification Label
English This
Side
French This
Side
Figure 8 - Applying English and French
Conversion Labels over Existing
Certification Labels on Lighting
Instruction Plate
DIRECT VENT DECORATIVE FIREPLACE
Conversion Kit Model
Type of Gas
®
Previous Model #
Figure 9 - Print Previous Model Number
on Conversion Labels
CONVERSION INFORMATION LABEL
This appliance was converted on
(name and address of organization making
this conversion), which accepts the
responsibility that this conversion has been
properly made.
Day Month Year
to gas
with Kit No.
by
106080-0156060
Figure 10 - Conversion Information Label
HI
LO
O
F
F
P
I
L
O
T
O
N
Mounting
Screws
Pressure
Regulator
Tower
Diaphragm/
Spring
Components
Lighting Instruction
Plate