The instruction plate is firmly attached to the purifier
for quick reference to important instructions. The plate
does not replace the complete manuals supplied with
the purifer. Do not remove or deface the plate.
SAFETY
8DM Series purifiers are designed and constructed
with safety as a prime consideration. Each purifier is
pressure tested to 1½ times its maximum operating
pressure.
DANGER
The following safety rules are crucial to en
-
sure safe purifier operation. Failure to follow
these 9 important rules may result in purifier
damage, inadequate purification, severe ill
-
ness, injury or death.
1. Do not allow grossly contaminated air into the pu-
rifier inlet. See Table I for maximum allowable in-
let carbon monoxide concentration.
2. Do not allow oxygen-deficient air into the purifier
inlet. The purifier will not increase the oxygen
content of air.
3. Contact Deltech if any unusual contaminants may
be in the compressed air. The purifier removes
only oil, moisture, particulates and carbon monox-
ide.
4. Do not operate the purifier at pressures, tempera
-
tures or flows above the maximum conditions
stamped on the data plate attached to the side
panel.
5. Do not use the purifier for any gases other than
compressed air.
6. Vent purifier internal pressure to the atmosphere
before disassembling any purifier parts.
7. Do not readjust the purifier without factory
authorization. The purifier is fully adjusted at the
factory.
8. Use only genuine Deltech replacement parts, ele-
ments and cartridges. Deltech bears no responsi-
bility for hazards that result if Deltech equipment
is used with non-approved parts.
9. Replace all cartridges according to the preventive
maintenance schedule starting on page 13 in this
manual.
INSTALLATION
Receiving and Inspection
Immediately on receipt of the purifier, check for dam
-
age that may have occurred during shipping. If there is
any damage, do not install or attempt to repair the pu
-
rifier. Installation and use of damaged equipment may
void the warranty or cause serious injury.
If the purifier is damaged, contact your local distribu
-
tor. Since the purifier is shipped F.O.B. New Castle,
Delaware, the carrier is legally responsible for any
damage incurred during shipping. Shipping damage is
not covered by the purifier warranty.
2 Pyramid 8000
®
Series Purifiers (Bulletin 289)
Danger Label: Grossly Contaminated Air
Part No. 56DE152A
Purifier Data Plate
Part No. 44DE23A