DeLonghi de 400 Dehumidifier User Manual


 
9
ENGLISH
Stand-by position
Once the power outlet is plugged in, the display will show on the left side the degree of humi-
dity you want to reach (the default data is 60) and on the right side the display will show (for
a minute) two dots, followed by the room humidity level.
How to Select the Desired Humidity Level
1) Push the stand-by button.
2) Press the button to set the desired humidty level. (30% means a dry environment,
80% a humid environment).
3) Push the MODE button to choose the dehumidifying function; the function is selected when
the small dot on the display is under the symbol).
4) When the appliance reaches the humidity set point the appliance will automatically stop
working. As soon as the humidity increases above the set point, the appliance will auto-
matically resume dehumidification operation.
Note: The appliance is equipped with a safety device. The appliance only works after 3 minu-
tes from the last time it was turned off.
How to use the FAN function
1) Push the stand-by button.
2) Push the MODE button to choose the FAN function; the function is selected when the small
dot on the display is under the symbol).
3) Press the button to modify the ventilation speed (min/med/max).
Turbo power
1) Press the button.
2) The turbo power function is an automatic dehumidification function that is used when you
wish to operate the appliance at maximum power. When in this mode, the display will show
on the left side (two dots) and on the right side the room humidity present.
To stop the turbo power function, simply press the button again.
How to program the delayed start function: From the OFF Position
1) With the unit OFF, press the button and use the button to set the number of
hours after which the appliance should start functioning.
2) On the left side the display will show the number of hours after which the appliance should
start the operation (1-24h) and a small dot under the symbol indicates that the timer
function has been selected.
3) When the selected time is reached, the appliance will start working.
Selecting the operations