ENGLISH
STAND-BY button
Press this button to start /stop the appliance. To turn the appliance completely off, remo-
ve the plug from the outlet.
Room temperature button
Press this button to display the Temperature on the LCD display. If you press the button once
the display will show the °F . If you press the button twice, the display will show the tempe-
rature in °C. After few seconds, the display will automatically show the humidity level.
FAN speed button
Press this button to select the Fan Speed (High, Medium, Low).
Decrease or increase Humidity Level/ Time buttons
These buttons are used to adjust the desired humidity level, with 5% increments; they are
also used to set the timer.
From 0 -10 the hours increase by 30 min. and from 10-24 the hours increase by 1 hour increments.
TIMER button
With the appliance switched ON, if you press the TIMER button the display will show the
hours after which you want the appliance to switch OFF (1-2-3... hours ).
With the appliance in the STAND-BY position, if you press the TIMER button the display will
show the hours after which you want the appliance to switch ON (1-2-3... hours ).
MODE button
Press this button to select the Fan only or Dehumidifier modes.
TURBO POWER button
Use this button to activate the “turbo power” function. In this mode, the appliance will
operate at maximum fan speed and in continuous mode. If pressed again, the unit will
revert back to previous settings.
PUMP button (only on pump models)
Use this button to activate the heavy-duty pump system for active drainage.