Dayton Installation, Operation, Maintenance and Parts Manual
Models 3E132 thru 3E134, 3E460 thru 3E462,
5VD57 thru 5VD66, 3VH34 thru 3VH37
E
N
G
L
I
S
H
5
Chart 1.1 - Clearance to Combustibles in Inches (see Figure 1.1)
NOTE: If the heater is mounted beneath a non-combustible surface, a 24 in. minimum top clearance must be
maintained from the top of the heater to prevent overheating the controls.
Figure 1.1 - Clearance to Combustibles Diagram
Side Side
Back
Manifold or
Control End
Below
Top
20°-35°
Front
Mount Heater Level
FRONT VIEW
Model No. BTU/H Gas Type Voltage Sides Back Top Below/Front
3E132 30,000 Natural 120V 30 18 28 72
3E460 30,000 Propane 120V 30 18 28 72
5VD61 30,000 Natural 24V 30 18 28 72
5VD62 30,000 Propane 24V 30 18 28 72
3E133 60,000 Natural 120V 32 18 40 72
3E461 60,000 Propane 120V 32 18 40 72
5VD63 60,000 Natural 24V 32 18 40 72
5VD64 60,000 Propane 24V 32 18 40 72
3E134 90,000 Natural 120V 48 30 42 98
3E462 90,000 Propane 120V 48 30 42 98
5VD65 90,000 Natural 24V 48 30 42 98
5VD66 90,000 Propane 24V 48 30 42 98
130,000 N or LP 24 or 120V 48 30 52 120
160,000 N or LP 24 or 120V 50 32 60 132
SIDE VIEW