Danby DPAC 12099 Air Conditioner User Manual


 
IMPORTANT: The exhaust hose must be properly
vented (outdoors) during air conditioning mode.
1) Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous
set temperature will be shown in the temperature display area of the control panel.
2) Press the MODE key (Fig. B) until the COOL indicator light illuminates on the
control panel (Fig.C). Each depression of the MODE key will advance to a different
mode setting (Cool-Dehumidifier-Fan-Heat-Auto)
3) Press the appropriate increase or decrease buttons (Fig. D) to select a
suitable operating temperature setting. Temperature settings are adjustable between
16°C (61°F) to 32°C (89°F).
4) Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High-
Med.-Low). Your selection will appear on the control panel (each depression of the
fan key will advance to a different setting).
• Cooling stops automatically when the set temperature is achieved. Cooling resumes
when the room temp. rises above the “set” temperature level.
Note: During dehumidifier mode, the exhaust hose does not
have to be vented outdoors.
1) Press the ON/OFF key pad to switch the unit on (Fig. A)
2) Press the MODE key (Fig. B) until the DRY indicator illuminates on the
control panel (Fig.G). Each press of the MODE key will advance to a different
mode setting (Cool-Dehumidifier-Fan-Heat-Auto).
3) If room temperature is >25°C (77°F), fan speed can be adjusted. Press the
FAN key (Fig. E) to select the desired FAN SPEED setting. Your selection will
appear on the control. Each depression of the fan key will advance to a
different fan speed as shown in Fig. F. Otherwise fan speed is fixed to “low”.
NOTE: The warm air exchange hoses must vent inside the room when using
Dehumidify Mode, not outside as in Cooling Mode.
DEHUMIDIFIER
7
OPERATING INSTRUCTIONS (cont’d)
AIR CONDITIONING
Fig. A
Fig. B
Fig. C
Green
Fig. F
Fig. D
Fig. E
High
Medium
Low
Fig. G
Orange
Fig. H
Fig. I
Fig. J
Yellow
Fig. K
Fig. L
Medium
High
Low
FAN
NOTE: During Fan Mode, the exhaust hose does not have to be
vented outdoors.
1) Press the POWER SWITCH key to turn the unit on (Fig. H).
2) Press the MODE key (Fig. I) until the FAN indicator illuminates on the
control panel (Fig. J). Each press of the MODE key will advance to a different
mode setting (Cool-Dehumidifier-Fan-Heat-Auto).
3) Press the FAN Key (Fig. K) to select the desired FAN SPEED setting. Your
selection will appear on the control panel. Each press of the fan key will
advance to a different fan speed (High- Med- Low) as shown in Fig. L.