Daewoo DPB-280LH Air Conditioner User Manual


 
36
7. TROUBLE SHOOTING
Outdoor unit does
not run?(note. 1)
Does
the compressor run
normally?
Indoor unit does
not run(note 1)
Check the failure
code according to
the self diagnostic
(note 2)
Is the unit
display
mormal?
check the failure
code according to
the self-diagonostic
(note 2)
Normal
check the
connecting
point of
magnetic
contactor
YES
YES
YES
YES
NO
NO
YES
Trouble
Is the power
applied to the
unit
Is the
power normal?
check the voltage between
L & N of terminal
block
press the power ON/OFF
button on remote controller
Does the
beeper beep two
times?
Is the display
all off?
Check the connector on display
PCB connected to control PCB
Check the display PCB itself
Check power supply mains
or interconnection wires
Check the wiring of indoor
Does
control PCB
status LED repeat one
second "on and
off"?
control PCB fault
Micom or reset
IC fault
Check the remote signal receiver
Check the connection between signal
receiver and control PCB
YES
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
NO
NO
Is the
unit display
normal?