2
1. INSTALLATION GUIDE
1
INSTALLATION PLACE
◆Indoor unit ◆Outdoor unit
Secure enough space from the neighboring objects as shown below.
This is required to operate the unit efficiently.
• Flat and strong place in the room
• No obstacles in front of air in/out grille
• Easy place to connect drain hose to outside of room
• Easy place to connect copper tube with outdoor unit
• Secure enough distance from neighboring objects as
shown below.
• Secure enough distance from neighboring objects as
shown below.
• A place no reach of direct ray of sun (if necessary, shield the
light)
• No obstacles in front of air in/out grille
• A place having a drain out-let
• Easy place to connect copper tube with indoor unit
• Secure enough distance from neighboring objects as shown
below.
100cm
5cm
10cm
50cm
10cm
50cm
(Indoor unit) (Outdoor unit)
Lquid
Gas
3/8”
5/8”
A
12~12.4
18.6~19
B
9.52
15.88
Unit: mm
Nominal diameter
Flare specification
Lquid
Gas
3/8”
5/8”
Unit: mm
Torque
300Kg • cm
500Kg • cm
Torque
B
CAUTION : Do not hang the outdoor unit on the wall of building, in case of falling, it may cause a serious trouble and damage.
2
SPACE TO INSTALL
◆ Specification and method of copper tube
• Connection method of copper tube is to make connection with flare nut at the end of the copper tube with a flare tool.