Daewoo DPB-280LH Air Conditioner User Manual


 
16
Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode, the unit will operate automatically by selecting
operating Mode according to the room temperature
(2) Selecting Operating Mode Again
Room temperature meets desired temperature and the compressor stops running over 30 minutes, then the unit
selects operating Mode again.
3 Seconds Time Delay of Indoor Fan Motor
When the speed of indoor fan motor changes, there is a time delay of 3 seconds at each speed step.
ROOM TEMPERATURE
DT+3˚C RT
DT-2˚C RT DT+2˚C
DT -2°C RT
OPERATING MODE
Cooling
Dehumidifier
Heating
RT: Room temperature
DT: Desired
()
3 min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
< <
>
<