Louisville Tin and Stove WOW253 Gas Heater User Manual


 
Page 5
FIGURE 2. VENT TERMINAL CLEARANCES
V VENT TERMINAL
X AIR SUPPLY INLET
AREA WHERE TERMINAL
IS NOT PERMITTED
Canadian Installations ¹ U.S. Installations ²
A = Clearance above grade, veranda, porch, deck, or balcony 12 Inches (30 cm) 12 Inches (30 cm)
B = Clearance to window or door that may be opened 6 Inches (15 cm) for appliances < 10,000 Btuh (3 kw), 12 inches (30 cm)
for appliances > 10,000 Btuh (3 kw) and <
100,000 Btuh (30 kw), 36
inches (91 cm) for appliances > 100,000 Btuh (30 kw)
6 Inches (15 cm) for appliances <
10,000 Btuh (
3
for appliances > 10,000 Btuh (3 kw) and < 50,0
0
inches (30 cm) for appliances > 50,000 Btuh (15
C = Clearance to permanently closed window *12 Inches (30 cm) recommended to prevent condensation on window *12 Inches (30 cm) recommended to prevent co
n
D = Vertical clearance to ventilated soffit located
above the terminal within a horizontal distance of
2 feet (61 cm) from the center line of the terminal
*18 Inches (46 cm)
*18 Inches (46 cm)
E = Clearance to unventilated soffit *12 Inches (30 cm) *12 Inches (30 cm)
F = Clearance to outside corner *12 Inches (30 cm) *12 Inches (30 cm)
G = Clearance to inside corner *24 Inches (60 cm) *24 Inches (60 cm)
H = Clearance to each side of center line extended
above meter/regulator assembly
3 feet (91 cm) within a height 15 feet (4.5 m) above the meter/regulator
assembly
Clearance in accordance with local installation c
o
requirements of the gas supplier.
I = Clearance to service regulator vent outlet 3 feet (91 cm) Clearance in accordance with local installation c
o
requirements of the gas supplier.
J = Clearance to nonmechanical air supply inlet to
building or the combustion air inlet to any other
appliance
6 Inches (15 cm) for appliances <
10,000 Btuh (3 kw), 12 inches (30 cm)
for appliances > 10,000 Btuh (3 kw) and <
100,000 Btuh (30 kw), 36
inches 91 cm) for appliances > 100,000 Btuh (30 kw)
6 Inches (15 cm) for appliances <
10,000 Btuh (
3
for appliances > 10,000 Btuh (3 kw) and < 50,0
0
inches (30 cm) for appliances > 50,000 Btuh (15
K = Clearance to a mechanical air supply inlet 6 Feet (1.83 m) 3 Feet (91 cm) above if within 10 feet (3 m) hor
i
L = Clearance above paved sidewalk or paved
driveway located on public property
7 Feet (2.13 m) † Clearance in accordance with local installation c
o
requirements of the gas supplier.
M = Clearance under veranda, porch, deck, or
balcony
12 Inches (30 cm) ‡ Clearance in accordance with local installation c
o
requirements of the gas supplier.
¹ In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code.
² In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated:
a.) A minimum clearance value determined by testing in accordance with section 4.7.3, 6.5.5, 8.5.5; or;
b.) A reference to the following footnote:
“Clearance in accordance with local installation codes and the requirements of the gas supplier.”