Louisville Tin and Stove BBT53 Gas Heater User Manual


 
Page 7
INSTALLATION - Cont’d.
STEP 2.
ROUGH IN GAS SUPPLY – (See Figure 3)
a) Select the bottom, rear or right side to bring the factory supplied flexible gas line assembly out of
the heater.
b) The valve must be connected only by means of a pipe union of the ground joint type.
Mr. Installer, hold gas valve when connecting gas supply line.
c) Install at least a 3/8” gas line. Contact local gas supplier if any questions.
d) Install a drip leg in gas supply line immediately upstream from the gas connection to heater, (see
local codes), and provide a 1/8” N.P.T. plugged tapping, accessible for test gauge connection and a
individual manual shut off valve accessible within room where heater is installed. The heater and
its individual shut off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ psig (3.5Pa). The heater must be
isolated from the gas supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig
(3.5Pa).
e) Test all connections for leaks using a soapy solution. NEVER USE AN OPEN FLAME TO TEST
FOR LEAKS.
f) The maximum inlet gas supply pressure for natural and L.P./Propane gas is ½ p.s.i. or 14” w.c.
The minimum inlet as supply pressure for the purpose of adjustment is 4.5” w.c. for natural gas
and 11.0” w.c. for L.P./Propane gas.
YOU SHOULD HAVE:
1 – Baseboard Heater
1 – Exhaust Tube
1 – Air Intake Tube
1 – 4” [10 cm] Stainless steel flexible
connector with a manual shut-off valve
1 – Template to locate venting and
mounting positions (in package with
manual)
1 – Vent Sealing Gasket
1 – Manual
1 – Weather Seal
1 - Wall thermostat w/wire & staples
STEP 3. PREPARING TO INSTALL THE
BASEBOARD HEATER
a) Open the carton and carefully remove the Direct
Vent Baseboard Heater.
b) Remove the cover of the baseboard heater’s
cabinet by removing the screws at the bottom
front of the cover. (See Figure 4.)
c) Make sure that all of the components illustrated
have been included.
[48” - 5M BTU] - - - [72” - 9M BTU]
1/2” BLACK IRON PIPE
FLEX LINE BALL VALVE MUST BE
ABOVE FLOOR
DRIP LEG
MANUAL SHUT OFF VALVE WITH 1/8” NPT PLUGGED TAPPING
2” FROM END OF CABINET
FLOOR
GAS SUPPLY
BASEBOARD CABINET
FIGURE 3
1/4”
Gas Baseboard Heater
48” - BBT53 & BBT54
72” - BBT103 & BBT104
FIGURE 4
Exhaust Tube
Indoor Intake Gasket
Air Intake Tube
Screws
Flex Line Ball Valve
Cabinet
Cover
Weather
Seal
Screws
FIGURE 4: COMPONENTS OF THE
DIRECT VENT GAS BASEBOARD
HEATER