Louisville Tin and Stove BBT53 Gas Heater User Manual


 
Page 2
Introduction……………………………..... 2
Specifications and Dimensions………...….. 2
Safety Rules…………………………….. 3
Clearances………………………………. 4, 5
Location………………………………… 5
Installation………………………………. 6 - 10
Lighting Instructions……………………... 11
Gas Conversion......................................... 12
Burner Orifice…………………………..... 13
Wiring Diagram…………………………... 14
Removing Main Burner………………....… 13
Proper Burner Flame………………...…… 13
Sequence of Operation……………......…. 15
Optional Kits………………………........16 - 20
Trouble Shooting…………………..…... 21 - 22
Parts Drawing…………………………..... 23
Parts List………………………………..... 24
Warranty………………………………..... 26
CONTENTS
INTRODUCTION
THIS IS A GAS-FIRED, DRAFT INDUCED, POWER DEPENDENT, DIRECT VENT WALL FURNACE;
THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN
INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND
OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING,
SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE
INSTRUCTIONS CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE
AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.
SPECIFICATIONS AND DIMENSIONS
Your Direct Vent Wall Furnace is shipped complete in one carton. This carton contains the furnace, vent
exhaust tube, air inlet tube, template with rough-in dimensions, installation and operating instructions, power
cord (consult electrical codes), ball-valve w/flex connector, and wall thermostat.
MODEL INPUT GAS TYPE MAX. WALL MIN. WALL
NO. BTU/HR. WIDTH DEPTH HEIGHT CONN. GAS Thickness Thickness
BBT53 5,000 BTU 48” 5.375” 9.375” 3/8” NAT. 16” 4”
1.45 KW 122cm 13.65cm 23.8cm 41cm 10cm
BBT54 5,000 BTU 48” 5.375” 9.375” 3/8” L.P. 16” 4”
1.45 KW 122cm 13.65cm 23.8cm 41cm 10cm
BBT103 9,000 BTU 72” 5.375” 9.375” 3/8” NAT. 16” 4”
2.61 KW 183cm 13.65cm 23.8cm 41cm 10cm
BBT104 9,000 BTU 72” 5.375” 9.375” 3/8” L.P. 16” 4”
2.61 KW 183cm 13.65cm 23.8cm 41cm 10cm
The State of Massachusetts requires that installation and service of a gas
appliance be performed by a plumber or gas fitter licensed in the
Commonwealth of Massachusetts.