Coway BA13-AE Plumbing Product User Manual


 
21
CLEANING AND MAINTAINING YOUR BIDET
Removing the product
1. Unplug the power cord from the electrical outlet.
2. Close the main water supply valve.
3. Pull the product forwards by holding both sides of the product while
pressing the button at the bottom left of the product, to separate
the product from the installation plate.
Unplug the product if it will not be used for a long time.
Tips
2. Remove the MESH filter at the bottom left of the product.
 -RemovetheMESHfilterbyturningitwitha‘+’screwdriver.
Cleaning the MESH lter
1. Separate the product from the installation plate.
 -RefertoRemovingtheproduct(1~3).
4. Remove the drain plug at the back of the bidet by turning it
counterclockwise by 90 degrees and then pulling it forwards so that
the water in the hot water tank is drained into the toilet.
1210964 BA13 사용설명서_수출영문_(09.03.23).indd 21 2009.3.24 10:13:22 AM