Cooper Lighting P4GE-MX Indoor Furnishings User Manual


 
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Door Latch: (Illustration 9)
Relamping:
(Illustration 10)
When re-lamping, turn power off and allow the luminaire to cool. Pror to installing the lamp, check that the lamp is of proper type and
wattage. Screw the lamp securely into socket, back the lamp out one to two turns, then screw the lamp back in, making sure it is
secured. This properly seats the lamp in socket.
Cleaning:
The reflector and door glass may be cleaned with any suitable, non-abrasive glass cleaning solution, soap or detergent and rinsed
with clean water.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-623 ACF050370
Small falcon
Sheet 5 of 7
1/26/05 IMI-623
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
6-32 door latch
securing screw
provided(not factory
installed). customer
may replace with a
tamper resistant
screw of their
choosing or order
Cat. No. SF/TRS if
desired.
To open door,
lift latch
and rotate
away from
door
ILLUSTRATION 9
ILLUSTRATION 10
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing lamp or handling fixture.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before handling fixture.
To open door, lift
latch and rotate
away from door.
Rotate door to open
for relamping and
maintenance.
6-32 door latch securing
screw provided (not factory
installed). Customer may
replace with a tamper
resistant screw of their
choosing (max. length 1/4”)
or order Cat. No. SF/TR if
desired.