Cooper Lighting P4GE-MX Indoor Furnishings User Manual


 
GREEN
W
H
ITE
B
L
A
C
K
GROUND
WHITE
WHITE
BLACK
WIRE NUT
INSULATED VOLTAGE
LEADS
BALLAST
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please
contact your nearest representative.
Voltage Wiring: (Illustration 4)
Some luminaire ballasts are provided with multiple voltage options. The ballast voltage must be properly selected to
match the incoming supply voltage. If it is necessary to change the ballast voltage, remove the wire nut from the black
supply wire. Remove the ballast voltage lead wire and insulate the bare end according to the local electric code. Select
the desired ballast voltage lead wire. Remove the insulation and connect the lead wire to the black supply wire using the
wire nut previously removed. Insure that all wire connections are properly secure and insulated according to the local
electric code.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-623 ACF050370
Small falcon
Sheet 3 of 7
1/26/05 IMI-623
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING LUMINAIRE.
RETAIN FOR FUTURE REFERENCE.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
CAUTION: The ballast voltage must be properly selected to match the incoming supply voltage or damage to the
ballast will occur
ILLUSTRATION 4
NOTE: Luminaire shown with lamp and
reflector removed.
Insulated Voltage
Leads
Ballast
Wire Nut
White
White
White
G
reen
Ground
Black
B
la
c
k