Cooper Lighting MD42FLW Indoor Furnishings User Manual


 
3
• Fixture should be installed by persons with experience in household wiring or
by a qualified electrician. The electrical system, and method of electrically
connecting the fixture to it, must be in accordance with the National Electrical
Code and local building codes.
• Always use same wattage and type of bulb that was included with the fixture.
Failure to do so will void the warranty.
Putting up your fixture
Note: This fixture is intended to be installed either on a standard lampholder
mounting plate, or with conduit, connected to a properly installed and properly
grounded metal weatherproof junction box (not included). All coverplates,
conduit connections, conduit, and junction boxes (not included) should be
Listed suitable for wet locations.
Mounting to wall or post:
Step 1: Using the pattern on the box, mark and drill holes for mounting.
Note: This fixture should be mounted in an upright position.
Step 2: Install the two bottom mounting screws (E) first, leaving enough room
between the mounting screws and the mounting surface to slide the
fixture into position.
Step 3: Screw the top mounting screw (E) into the predrilled hole and back the
screw out. This will leave the hole threaded and make installation of
the fixture easier.
Step 4: Mount the light fixture (without the access cover) to the mounting
surface by setting the fixture on the bottom two screws - from Step 2
(in the slots on the bottom of the fixture plate), and then screwing the
top screw back into the pre-threaded hole. Tighten all screws.
Step 5: Remove the access cover (C) from the hardware bag. With a hammer
and screwdriver, remove the round knock-out from the access cover
(be careful not to damage the access cover).
Step 6: Install the first conduit connector (not included)
into the knock-out area of the access cover (Fig 1).
Tighten with adjustable wrench.
Note: The access cover should not be attached to the unit at
this point.
Step 7: Connect second conduit connector at the junction
box (Fig. 1).
Step 8: Attach conduit between the two connectors.
Step 9: Turn off the power at the main fuse/breaker box. Feed supply
wires into conduit, connecting one end inside junction box, and the
other end to the fixture. Make wiring connections inside
the fixture arm as described in “Wiring your fixture.”
Mounting to standard lampholder mounting plate:
Step 1: Feed the supply wires from the house through the
lampholder mounting gasket, and through the back
of the mounting plate itself (Fig. 2).
Fig. 1
Fig. 2
Call for customer service and/or missing or damaged parts (800-334-6871)
ENGLISH
MD42FLW_FLB 825-0132.qxd:MD Series 325-1432.qxd 5/28/08 8:26 PM Page 3