resistant to the corrosive action of propane.
To check for leaks, always use a soapy water solution or a
sniffer.
Never test by using an open flame.
The area around the gas logset must be free of all combus-
tible materials, especially gasoline or other highly flammable,
vapor producing liquids.
Due to high temperatures, locate this logset away from both
high traffic areas and furniture and draperies.
Children and adults alike should be aware of the high
surface temperatures; to avoid the risk of burns or ignition of
clothing they should stay away.
Do not touch any part of the logset other than the controls
while it is operating or immediately after you turn it off.
Supervise young children and pets carefully when they are
in the room where the logset is operating.
Do not place clothing or other flammable material on or near
the logset.
Make sure that any safety screen or guard, removed during
servicing, has been replaced before you use the logset.
Do not, under any circumstances, install the logset in any
bedroom, bathroom, other small, enclosed room, mobile home
or recreational vehicle.
Do not install the logset in a drafty area or use it with any
after-market blower system that may cause drafting and con-
sequently alter the flame pattern.
It is imperative that you keep clear all burner areas, control
compartments and passageways for circulating air.
Do not move the logset in any way that might dislodge the
logs from their fixed positions. If you bump the logset check to
see if you have dislodged anything.
Provide adequate clearances around air openings into the
combustion chamber and adequate accessibility clearance
for servicing and proper operation. NEVER obstruct the front
opening of the fireplace.
Avoid propane tank dropping below 25% full. This will help
keep soot from occurring.
General Information
In order to assure a safe and effective instal-
lation, only a qualified service person who is
familiar with the building codes and installation
techniques appropriate to your area may install
and service this appliance.
The Logsets have been designed and tested to operate
safely when installed according to the installation instructions
contained in this manual. Read all instructions before starting
the installation.
In the Commonwealth of Massachusetts, all gas fitting
and installation of this heater shall only be done by a
licensed gas fitter or licensed plumber.
The vent-free gas logset must be installed only in a fire-
place constructed of noncombustible material.
These logsets are not for exterior use.
This appliance is for supplemental heating only. It should not
be used as the primary heat source for a dwelling.
The logset should be inspected before use and at least an-
nually thereafter. More frequent cleaning may be necessary
due to excessive lint from carpeting or bedding material.
In the United States, the installation and operation must
conform to local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, latest
edition, CSA-B149.1 Installation Code, and with the National
Electrical Code, ANSI/NFPA70 (latest edition). State or local
codes may only allow operation of this appliance in a vented
configuratio. Check your state or local codes. In Canada,
check local province for proper use or CSA-B149. Refer to
pages 7 and 8 for installation details.
The gas logset and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 p.s.i.g. (3.5 kPa.) The gas logset must be isolated from
the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas sup
-
ply piping system at test pressures equal to or less than 1/2
p.s.i.g. (3.5 kPa.)
Do not, under any circumstances, burn solid fuel (wood,
paper, coal) in the fireplace where you have installed your log
-
set. Do not use it for cooking. Put nothing on top of the logs.
The logset must be compatible with its fuel. Natural gas
requires different hardware than propane. Never attempt to
use natural gas with a propane logset or vice versa.
For a propane burning logset, the supply tank must include
a high to low gas pressure regulator. The tank
must be out-
doors. Do not, under any circumstances, locate supply tanks
inside any structure.
The fireplace must include a screen made of chain mesh
or a similar material. You must keep the screen closed at all
times during the operation of the logset; it will protect you in
the event of an explosion.
WARNING: If the fireplace contains glass doors, they must
remain open at all times during the operation of the logset,
allowing combustion air to circulate.
In order to avoid any possible gas leaks, apply pipe joint
compound to all non-flared, threaded connections involved
in this installation. For propane, the joint compound must be
WARNING
This appliance is for installation in a solid-fuel
burning masonry fireplace with a working flue,
a U.L.-127 Listed manufactured solid-fuel burn-
ing fireplace, in any CFM Corporation ventless
firebox or in any listed ventless firebox enclo
-
sure certified to I.A.S. U.S. requirements 2-97.
NOTICE
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed. Pro-
visions for adequate combustion and ventilation air
must be provided. Refer to pages 5 and 6.
This appliance operates as an unvented domestic room
heater when fitted to a masonry or factory-built wood-
burning fireplace with the flue damper closed, or as
a decorative appliance when the flue damper is fully
open. It must not be used for any other purpose and
must be fitted in a masonry or factory-built fireplace or
ventless firebox enclosure.