Desa Tech S39NT Stove User Manual


 
14
107434
VENT-FREE NATURAL GAS PEDESTAL STOVE
For more information, visit www.desatech.com
Figure 22 - Pilot
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.
8. Turn control knob counterclockwise
C-clockwise
to desired heating level. The
burners should light. Set control knob
to any heat level between HI and LO.
TO TURN OFF GAS
TO APPLIANCE
1. Follow steps 1 through 5 under Light-
ing Instructions, page 13.
2. Depress control knob and light pilot
with match.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8 in column 1.
Shutting Off Heater
Turn control knob clockwise
Clockwise
to
the OFF position.
Shutting Off Burners Only (pilot
stays lit)
Turn control knob clockwise
Clockwise
to
the PILOT position.
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to
any comfort level between Hi and Lo. The
thermostat will gradually modulate the heat
output and flame height from higher to
lower settings, or pilot, in order to maintain
the comfort level you select. The ideal com-
fort setting will vary by household depend-
ing upon the amount of space to be heated,
the output of the central heating system, etc.
MANUAL LIGHTING
PROCEDURE
Thermocouple
Pilot Burner
OPERATING
HEATER
Continued
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 23 shows a correct pilot flame pat-
tern. Figure 24 shows an incorrect pilot
flame pattern. (
Note:
Appearance of pilot
assembly may vary by model). The incor-
rect pilot flame is not touching the thermo-
couple. This will cause the thermocouple to
cool. When the thermocouple cools, the heater
will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 24
turn heater off (see To Turn Off Gas to
Appliance)
see Troubleshooting, pages 16 through 18
Figure 23 - Correct Pilot Flame Pattern
Figure 24 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
CAUTION: Do not try to adjust
heating levels by using the equip-
ment shutoff valve.
Ignitor Electrode
Note:
Selecting the Hi setting with the
control knob will cause the burners to
remain fully on, without modulating down
in most cases.
Continued
Light your gas appliance with the blower
off. Turn the blower on to deliver heated
air at the top louvers. The blower fea-
tures a variable control which allows you
to select the speed you desire.
If using the GA3650TA Blower Accessory:
In the ON position, the blower will start
when the thermostat senses a sufficient
increase in firebox temperature (approxi-
mately 10 to 20 minutes depending on
heat setting).
Note:
Your gas stove and
thermostat blower will not turn on and
off at the same time. The stove may run
for several minutes before the blower
turns on. After the heater modulates to
the pilot position, the blower will con-
tinue to run. The blower will shut off
after the firebox temperature decreases.
Note:
It is safe to operate stove with
blower turned off. However, the blower
helps distribute heated air from the stove.
Note:
Periodically check the louvers of
the firebox and remove any dust, dirt, or
other obstructions.
OPERATING
OPTIONAL BLOWER