OPERATING HEATER
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire de-
partment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
Pressure Testing Heater Gas Connections
1. Open equipment shutoff valve (see Figure 20, page 12).
2. Open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to control valve
(see Figure 21, page 12). Apply noncorrosive leak detection
fluid to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater). Check all other internal
joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 14).
Figure 22- Control Knob and Ignitor Button Location
1. STOP! Read the safety information, column 1.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise
Clockwise
to the OFF position.
4. Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, column 1. If you don’t
smell gas, go to the next step.
5. Turn control knob counterclockwise
C-clockwise
to the PI-
LOT position. Press in control knob for five (5) seconds
(see Figure 22).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
6. With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure, page 14.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of new heater, burning
logs will give off a paper-burning smell. Orange flame
will also be present. Open a window to vent smell. This
will only last a few hours.
Control Knob
Ignitor Button
INSTALLATION
Continued
Figure 23 - Pilot
Thermocouple
Pilot Burner
INSTALLATION
Checking Gas Connections (Cont.)
OPERATING HEATER
For Your Safety Read Before Lighting
Lighting Instructions