25
105983
OWNER’S MANUAL
O
F
F
P
I
L
O
T
O
N
L
O
I
H
ON
OFF
REMOTE
ON
OFF
TEMP
STATUS
HI
LO
MAN ON
AUTO OFF
OPERATING
FIREPLACE
Continued
Figure 55 - Hand-Held Thermostat Remote Control Unit Selections (CGHRCT)
Increases Room
Temperature
Decreases Room
Temperature
Turns Burners
On and Off
Shows Current
Operation Mode
Shows Temperature
Setting
Allows Burners to be
Turned On and Off
with the Hand-Held
Remote Unit.
The Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected.
Blower Control Knob
(Optional Accessory)
Variable
Control Knob
Selector Switch in
Remote Position
Gas Control
Knob in ON
Position
Figure 54 - Setting the Selector Switch,
Gas Control Knob, and Variable Control
Knob for Remote Operation
CGHRC Series Operation:
2a. Press the ON/OFF button to turn the
burners on and off. When turning
burners off, the pilot will remain lit.
CGHRCT Series Operation:
2b. Select the MAN (manual) or AUTO
button on the hand-held remote con-
trol unit (see Figure 55).
In manual mode, turn burners on
or off by pressing the ON or OFF
buttons on the hand-held remote
control unit.
In auto mode, the room tempera-
ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
perature, press the top arrow of the
TEMP button. To lower the room
temperature, press the bottom ar-
row of the TEMP button. At higher
settings the heater will run more.
1. After lighting, let pilot flame burn for
about one minute. Turn gas control
knob to ON position. Adjust variable
control knob anywhere between HI
and LO. Slide the selector switch to
the REMOTE position (see Figure
54).
Note:
The burners may light if
hand-held remote ON button was on
when selector switch was last turned
off. You can now turn the burners on
and off with the hand-held remote
control unit.
IMPORTANT
: Do not leave the selec-
tor switch in the REMOTE position
when the pilot is not lit. This will
drain the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
on page 24.
OPTIONAL REMOTE
OPERATION
Thermostat Control Operation
(Optional CGHRCT Only) The thermo-
stat control setting on the remote control
unit can be set to any comfort level be-
tween HI and LO. The burners will turn
on and off automatically to maintain the
comfort level you select. The ideal com-
fort setting will vary by household de-
pending upon the amount of space to be
heated, the output of the central heating
system, etc.
Note:
All remote control accessories must
be purchased separately (see Accessories,
page 36). Follow instructions included
with the remote control.
IMPORTANT:
This remote control
has been specially engineered to
take an air temperature sample ev-
ery 5.5 minutes in the auto mode.
It will not respond immediately to
the temperature setting being
turned up or down.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the
hand-held remote control unit will
heat up too quickly and turn the
heater off.
3. Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.
4. To turn the burners off when operat-
ing in the manual mode, press the OFF
button. If operating in the auto mode,
press the MAN button, then press the
OFF button. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the gas control knob on
the heater to the OFF position.
Continued