DIRECT-VENT FIREPLACE (NATURAL/PROPANE/LP)
CHDV37N/P AND CHDV41N/P
O
F
F
P
I
L
O
T
O
N
L
O
I
H
ON
OFF
REMOTE
ON
OFF
TEMP
STATUS
HI
LO
MAN ON
AUTO OFF
OPERATING
FIREPLACE
Continued
Figure 55 - Hand-Held Thermostat Remote Control Unit Selections (GHRCT)
Increases Room
Temperature
Decreases Room
Temperature
Turns Burners
On and Off
Shows Current
Operation Mode
Shows Temperature
Setting
Allows Burner(s) to
be Turned On and
Off with the Hand-
Held Remote Unit.
The Heater will
Automatically Cycle
between Pilot and the
Heat Setting that has
been Selected.
Blower Control Knob
(Optional Accessory)
Variable
Control Knob
Selector Switch in
Remote Position
Gas Control
Knob in ON
Position
Figure 54 - Setting the Selector Switch,
Gas Control Knob, and Variable Control
Knob for Remote Operation
OPERATING
OPTIONAL BLOWER
ACCESSORY
Locate the blower controls by opening
the lower louver panel on the fireplace.
Blower controls are located on the left
side of the switch bracket to the left just
inside the louver panel.
Both the GA3750 manual blower and the
CDA3620T thermostatically-controlled
blower have an ON setting and an OFF
setting. The blower will only run when the
switch is in the ON position. In the OFF
position, the blower will not operate.
Note for CDA3620T Only:
If you are
using CDA3620T blower, your fireplace
and blower will not turn on and off at the
same time. The fireplace may run for
several minutes before the blower turns
on. After the heater modulates to the pilot
position, the blower will continue to run.
The blower will shut off after the firebox
temperature decreases.
The blower helps distribute heated air
from the fireplace. Periodically check the
louvers of the firebox and remove any
dust, dirt, or other obstructions that will
hinder the flow of air.
HAND-HELD REMOTE
OPERATION
The thermostat control setting on the
remote control unit can be set to any
comfort level between HI and LO. The
burners will turn on and off automati-
cally to maintain the comfort level you
select. The ideal comfort setting will vary
by household depending upon the amount
of space to be heated, the output of the
central heating system, etc.
1. After lighting, let pilot flame burn for
about one minute. Turn gas control
knob on the control valve to ON posi-
tion. Turn variable control knob any-
where between HI and LO. Slide the
selector switch to the REMOTE posi-
tion.
Note:
The burner(s) may light
if hand-held remote ON button was
on when selector switch was last
turned off.
You can now turn the burners on and
off with the hand-held remote control
unit.
IMPORTANT:
Do not leave the selec-
tor switch in the REMOTE position
when the pilot is not lit. This will drain
the battery.
IMPORTANT:
Be sure to press the
ON/OFF buttons on the hand-held
remote control unit for up to 3 sec-
onds to assure proper operation.
2. Select the MAN (manual) or AUTO
button on the hand-held remote con-
trol unit (see Figure 55).
In manual mode, turn burners on
or off by pressing the ON/OFF but-
tons on the hand-held remote con-
trol unit.
NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See
Lighting
Instructions
. page 25.
In auto mode, the room tempera-
ture is controlled by the thermo-
stat in the hand-held remote con-
trol unit. To increase the room tem-
perature, press the top arrow of the
TEMP button. To lower the room
temperature, press the bottom ar-
row of the TEMP button. At higher
settings the heater will run more.
IMPORTANT:
The hand-held re-
mote control unit must be near the
heater but not extremely close to it.
The thermostat on the hand-held
remote control unit will heat up too
quickly and turn the heater off.
3. Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used.
4. To turn the burners off when oper-
ating in the manual mode, press the
OFF button. If operating in the auto
mode, press the MAN button, then
press the OFF button. The pilot will
remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the gas control knob
on the heater to the OFF position or
set selector switch to OFF position.