INSTALLING
Continued
A.G.A. Design-Certified Manual Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
From Gas Meter
(5" W.C. to 10.5" W.C.
Pressure)
Approved
Flexible
Gas Line
Tee Joint
Pipe Nipple
Cap
Sediment
Trap
Figure 16 - Gas Connection
Figure 17 - Removing Log Base Assembly From Fireplace
Continued
WARNING ICON G001
CAUTION
Do not pick up log base assembly by burners. This could damage
burners. Only handle base by grates.
Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to LP gas, not provided)
1. Remove fireplace screen. Remove two screws that hold fireplace screen in
place for shipping. These screws are located near top of screen. Discard
screws. Lift fireplace screen up and pull out to remove.
2. Remove access door from rear or side of fireplace. See Product Identification,
page 4, for access door locations.
3. Remove screws that attach log base assembly to fireplace (see Figure 17).
Carefully lift up log base assembly and remove from fireplace (see Figure 17).
CONNECTING FIREPLACE TO GAS SUPPLY
* Purchase the optional A.G.A. design-certified manual shutoff valve from your