Coleman FC9V Furnace User Manual


 
246786-CTG-B-0407
6 Unitary Products Group
Thermostat Chart - HP
HP24 Two Stage H/P - H*5B, YZE - w/Variable 2 Stage Furnace, 2 Stage Cooling Ready - PV8/9, (F,L)*8/9V, (G,L)*8/9V, XYG8V-*, XYF8V-*, XYG9V-*, XYF9V-*
W/031-01996- Series Demand Control; Hot Heat Pump Mode OR Conventional
Thermostat Installer Setup Number 0200 -
Backup Heat Source - must be set to 1 - Heat
Pump Backup Heat Source is Fossil Fuel
Thermostat Installer Setup Number 0210 -
External Fossil Fuel Kit - must be set to 0 -
External Fossil Fuel Kit is Controlling Heat
Pump Backup Heat
Change FFuel Jumper on
Heat Pump to ON
Thermostat Installer Setup Number 0190 -
Reversing Valve (O/B) Operation - must be
set to 0 - O/B Terminal Energized in Cooling
Step 1 of Thermostat User
Configuration Menu must be
set to Heat Pump 2
E2/P Switch must be in the E2 position
and the Humidistat Jumper on CFM
Control must be in the 'YES' position for
Dehumidification
( ) CONVENIENCE TERMINAL. NO
FUNCTION IN THIS APPLICATION.
24V HUMIDIFIER
(Optional)
Thermostat Installer Setup Number 0170 -
System Type - must be set to
12 - 3 Heat/2 Cool Heat Pump
Selection of GAS/ELEC switch
on thermostat not necessary
Step 1 of Thermostat User Configuration
Menu must be set to Heat Pump 2
Set W2 Delay on furnace to OFF
HM
Humidistat
BSG
Bonnet Sensor
Bonnet Sensor (Optional)
BS
Bonnet Sensor
AUX
Auxiliary Heat
E/W1
First Stage Auxiliary Heat
E/W1
First Stage Auxiliary Heat
W
Auxiliary Heat
Y2
Second Stage Heat/Cool
DHM
Dehumidistat
HUM
Dehumidification - Open on Humidity Rise
Y2
Second Stage Heat/Cool
Y2
Second Stage Heat/Cool
Y2
Second Stage Heat/Cool
(Y 2)
O
Reversing Valve–Energized in Cool
L
Malfunction Light
L
Malfunction Light
L
Malfunction Light
(X/L)
Malfunction Light
X/L
Malfunction Light
O/B
Reversing Valve
O
Reversing Valve–Energized in Cool
O
Reversing Valve–Energized in Cool
(O)
Reversing Valve–Energized in Cool
CFM CONTROL
G
Fan
G
Fan
G
Fan
G
Fan
W1 OUT
First Stage Auxiliary Heat Output
W2
Second Stage Auxiliary Heat
W2
Second Stage Auxiliary Heat
W2
Second Stage Heat
W2 OUT
Second Stage Auxiliary Heat Output
E
Emergency Heat
W/W1
Single/First Stage Heat
Y2 OUT
Second Stage Cool Output
R
24-Volt Hot (Heat XFMR)
R
24-Volt Hot
R
24-Volt Hot
R
24-Volt Hot
R
24-Volt Hot
RC
24-Volt Hot (Cool XFMR)
Y/Y2
Single/Second Stage Cool
C
24-Volt Common
C
24-Volt Common
Y
First Stage Heat/Cool
Y1
First Stage Heat/Cool
Y1
First Stage Heat/Cool
Y1
First Stage Cool
Y1
First Stage Heat/Cool
*DP22U70124 *PP32U72124
C
24-Volt Common
C
24-Volt Common
C
24-Volt Common
TWO STAGE
HEAT PUMP
*PP32U70124 *DN22H00124
*PP32U71124
THERMOSTAT THERMOSTAT THERMOSTAT
VARIABLE SPEED
FURNACE CONTROL