Operation
Turn cylinder valve on.
DANGER
• EXPLOSION - FIRE HAZARD
• Never store propane near high heat, open flames, pilot lights, direct
sunlight, other ignition sources or where temperatures exceed 120
degrees F (49°C).
• Propane is heavier than air and can accumulate in low places. If you
smell gas, leave the area immediately.
• Never install or remove propane tank while fireplace is lighted, near
flame, pilot lights, other ignition sources or while fireplace is hot to touch.
• This fireplace is red hot during use and can ignite flammables too
close to the burner. Keep flammables at least two feet from sides & eight
feet from top. Keep gasoline and other flammable liquids and vapors
well away from fireplace.
• The propane tank must always be stored outdoors in a well ventilated
space. Never store propane tank in an enclosed area (house, garage,
etc.). If fireplace is to be stored indoors, disconnect the propane tank for
outdoor storage.
• CARBON MONOXIDE HAZARD
• For outdoor use only. Never use inside house, or other unventilated
or enclosed areas. This fireplace consumes air (oxygen). Do not use
in unventilated or enclosed areas to avoid endangering your life.
DANGER
Do not attempt to operate until you have read & understand all General
Safety Information in this manual and all assembly is complete & leak
checks have been performed.
Lighting Instructions for FIREPLACE
1. Push in and rotate (counter
clockwise) control knob to the start
position and release.
Shut Down Procedure
1. Rotate control knob (clockwise)
to start position.
2. Push in on control knob and
rotate (clockwise) to OFF position.
3. Turn LP bottle valve off.
Note: If burner fails to remain light
ed, all valves should be closed and
a waiting period of at least 5
min
utes should pass before attempting
to light.
4. Rotate control knob to LOW or
HIGH position as desired.
Storage
Disconnect fireplace from propane tank before long
term storage of either the cylinder or the fireplace.
1. Turn cylinder valve off.
2. Disconnect regulator from cylinder.
3. Remove tank from fireplace.
4. Store propane tank in safe manner. Refer to Chapter 5 of Standard for
Storage and Handling of Liquefied Gases, ANSI/NFPA 58. Follow all
local codes. Always store propane tanks outdoors.
5. Store fireplace in a dry, clean, and safe place.
• BURN HAZARD
• Do not touch or attempt any maintenance on Heater for at least one
hour after use.
• Make sure all controls are off and propane tank has been removed
before doing maintenance.
WARNING
To enjoy years of outstanding performance from your fireplace
perform the following maintenance activities on a regular basis:
Keep exterior surfaces clean.
Use warm soapy water for cleaning. Never use flammable or
corrosive cleaning agents.
While cleaning your unit, be sure to keep the area around the
burner dry at all times.
Air flow must be unobstructed. Keep controls, burner, and circu-
lating air passages clean. Signs of possible blockage include:
– Gas odor.
– Fireplace makes popping noises.
– Smoky flame.
Spiders and insects can nest in burner orifices. This condition
can damage fireplace and render it unsafe for use. Clean burner
holes by using a heavy-duty pipe cleaner. Compressed air may
help clear away small particles.
Carbon deposits may create a fire hazard. Clean burner with
warm soapy water if any carbon deposits develop.
• Carbon may form on logs. If this occurs carbon can be removed
with warm soapy water or a soft bristle brush.
• If fireplace has been left uncovered and is wet from rain, snow,
yard sprinklers, etc., allow to dry (at least 30 minutes prior to use).
NOTE: In a salt-air environment (such as near an ocean),
corrosion occurs more quickly than normal. Frequently check for
corroded areas and repair them promptly.
Maintenance
Note: Initial lighting after gas cylinder change can take up to one
minute to purge any air that may be in the line.
3. Burner will ignite and be visible. Continue to push control knob in for
30 to 60 seconds and then release knob. Burner must remain on, if not
return to Step 1.
Warning: Do not lean over appliance while attempting to light.
Install cover.
2. Push in on control knob and
push Igniter knob until unit is
lighted.
Attention: It is not recommended that
this appliance be used if winds are in
excess of 10 mph.
Burner may be lighted with match if needed. Recommernded that a long
fireplace match may be used.
Battery Installation
1. Unscrew red igni-
tor button to reveal
battery compartment.
2. Install AA battery
with positive (+)out-
ward.
3. Replace ignitor
button finger tight.