Page -20- Clarke
®
Operator's Manual -Encore S30/L30
Do These Procedures When You End Your Work
1. Drain the solution tank (Figure 25) and the recovery
tank (Figure 26). To drain the tanks , follow this
procedure:
a. Turn the key switch “OFF”.
b. Remove the drain hose from the back of the
machine.
c. Put the end of the hose over a drain or bucket.
d. Recovery Tank:
1.) Turn the valve handle to the left. Pull the
handle out to open the drain (Figure 27).
NOTE: Have the opening in the side of the valve away
from you when you open the valve.
2.) To open the valve completely, turn the
handle to the right. Pull the handle out of
valve (Figure 28).
Solution Tank:
When hose is lowered to water level, water will
flow.
2. Flush the tanks. To flush the tanks, put clean water in
the tank through the opening on top of the tank.
3. If a tank or drain hose has an obstruction, use a pressure
water hose to flush the tank or hose. Put the water hose
into the drain hose.
4. Leave the tanks and the recovery drain valve open to dry
in the air.
5. Check the squeegee blade. Use a cloth to clean the
squeegee blade. If the squeegee blade is damaged or
worn, turn or replace the blade.
6. Check and clean the solution lid gasket. Use a mild
cleaning solution and rinse the parts in clean water.
Check the batteries and if necessary add distilled water
after charging. The correct level is within 1/4 inch (1/2 cm)
of the bottom of the tube in each cell.
CAUTION: Tap water may contain contami-
nants that will damage batteries.
Batteries must be refilled with
DISTILLED WATER ONLY.
WARNING: Lead acid batteries generate
gases which can cause an explo-
sion. NO SMOKING. Always wear
eye protection and protective
clothing when working near
batteries.
Use a clean cloth and wipe the surface of the machine.
Charge the batteries. See the instruction in the section of
this book called “How To Charge The Batteries”.
Maintenance
Figure 25
Figure 26
Figure 27
Figure 28
IVIE Enterprises – Website: www.ivie-ent.com - Order Parts Online