Page -24- CLARKE TECHNOLOGY Operator's Manual -Encore L26 Cylindrical
6. Locate the four mounting studs on the brush head
bracket. See figure 37. The top two mounting nuts
can be accessed through the top of the solution
tank. The lower two can be accessed through the
front. Loosen the four mounting nuts 2 to 3 turns
counterclockwise. NOTE: Do not remove mounting
nuts.
7. The brush head assembly can slide to the right side
by one inch or placed back into the center. Slide the
brush head assembly all the way to the ends of the
slots for the desired position. This insures that the
head operates straight up and down.
8. After repositioning the brush head, tighten nuts
securely to approximately 236 inch-lbs.
9. Close the front cover.
10. Close the recovery tank.
How to Level the Cylindrical Brush Head
The brush head on the Encore L26 is level when shipped
from the factory. If during use it becomes necessary to re-
level the head from side to side, follow this procedure:
1. Move the machine to a level area of the floor surface.
2. Turn key switch "OFF".
3. Lossen the 4 mounting nuts shown in figure 37, by
following steps in the procedure above (How to
Center or Offset the Brush Head).
4. Turn the key switch on and lower the head, until the
full weight of the head is on the floor.
5. Turn the key switch "OFF".
6. After determining the brush head is level with the
floor, tighten nuts securely to approximately 236
inch-lbs.
7. Close front cover and recovery tank.
Maintenance cont.
1
2
3
4
Figure 37