Chicago Electric 95591-.75 HP Water Pump User Manual


 
SKU 95591/95592/95593 For technical questions, please call 1-800-444-3353 PAGE 2
SPECIFICATIONS
Model 95591 Model 95592 Model 95593
Motor 115 V~ / 60 Hz / 4 A
/ 3/4 HP
115 V~ / 60 Hz / 5.5 A
/ 1 HP
115 V~ / 60 Hz / 6 A
/ 1.5 HP
Power Switch Type Automatic Float Switch
Power Plug Type 3-Prong / Grounded
Self Priming Yes
Maximum Pumping Capacity 3,000 GPH 3,300 GPH 3,700 GPH
Maximum Delivery Height 20’ 24’ 26’
Discharge Diameter 1-1/2 NPT Female / 1-3/4 NPT Male
Max. Operating Temperature 95° Fahrenheit
SAVE THIS MANUAL
You will need this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures, parts list and assembly
diagram. Keep your invoice with this manual. Write the invoice number on the inside
of the front cover. Keep this manual and invoice in a safe and dry place for future refer-
ence.
GENERAL SAFETY RULES
WARNING! Read all instructions
Failure to follow all instructions listed below may result in electric shock,
re, and/or serious injury. The term “power tool” in all of the warnings listed
below refers to your line-operated (corded) power tool or battery-operated
(cordless) power tool.
SAVE THESE INSTRUCTIONS
WORK AREA
Keep your work area clean and well lit.1. Cluttered benches and dark areas invite
accidents.
Do not operate power tools in explosive atmospheres, such as in the pres-2.
ence of ammable liquids, gases, or dust. Power tools create sparks which
may ignite the dust or fumes.
Keep bystanders, children, and visitors away while operating a power tool. 3.
Distractions can cause you to lose control. Children and other unauthorized peo-
ple should not be allowed in the work area.
REV 08b