18
Wall installation (optional)
Door
Track
Attach with
concrete anchors
(not provided)
Sensor Beam
No Higher
Than 6" (15 cm)
Above Floor
Fasten 2x4 to
Wall with Lag
Screws (Not
Provided)
Lag Screws
(Not Provided)
Sensor Beam
No Higher
Than 6" (15 cm)
Above Floor
Inside Garage Wall
Assemble Safety Reversing Sensors Mount Brackets
Floor installation (optional)
Indicator
Light
Lens
Sensor Beam
No Higher
Than 6" (15cm)
Above Floor
OR
Mount Brackets: Mounting Options
Garage door track installation (preferred)
C16 Wing Nut
C14 Carriage Bolt
ALL HARDWARE SHOWN ACTUAL SIZE
INSTALL THE PROTECTOR SYSTEM
®
A9
Extension Bracket
Inside
Garage
Wall
(Provided with
Extension Bracket)
(Provided with
Extension Bracket)
OR
Wall installation with Extension
Brackets (optional)
Sensor Beam
No Higher Than
6" (15 cm)
Above Floor
1
2
2a
2c2b
A10
Safety Sensor
Bracket
A17
Safety Reversing
Sensor
A17
Safety Reversing
Sensor
C14
Carriage
Bolts
C14
Wing Nut
Safety Reversing Sensors
MUST be aligned and no
higher than 6" (15 cm)
above floor
Safety Reversing Sensors
MUST be aligned and no
higher than 6" (15 cm)
above floor
NOTE: The safety reversing sensor must
be connected and aligned correctly before
the garage door opener will move in the
down direction.