Chamberlain 916GA Home Security System User Manual


 
Inside Property
Metal
OR
Wood
ENTRAPMENT
Safety Sensor Posts
OPEN
Safety Sensor Posts
Inside Property
Outside Property
CLOSE
Safety Sensor Posts
Inside Property
6" (15 cm) trench for
safety sensor wires
OPEN SAFETY SENSORS
Inside Property
6" (15 cm) trench for
safety sensor wires
Outside Property
6" (15 cm) trench
for safety sensor
wires
CLOSE SAFETY SENSORSENTRAPMENT SAFETY SENSORS
NOTE: For ideal protection the safety sensors should be installed as close
to one another as possible with the maximum distance up to 30' (9.1 m).
To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging.
ATTENTION
AVERTISSEMENT AVERTISSEMENT
AVERTISSEMENT
WARNING
CAUTIONCAUTION
WARNING
WARNING
PRECAUCIÓN
ADVERTENCIA
ADVERTENCIAADVERTENCIA
2
SAFETY SENSOR POSTS
Use a metal or treated wood post (not provided) to elevate the sensors.
Safety sensors must be installed no higher than 24" (61 cm) above the
ground.
POWER
Disconnect power and batteries to the operator.
TRENCH FOR WIRING
Before digging, contact local underground utility locating companies.
Dig a narrow trench 6" (15 cm) deep from control box to safety sensor
posts. Be careful not to damage any buried wire. Run conduit from
control box to safety sensor posts and run low voltage wire* (not
provided) through conduit.
* UL approved Class 1 or Class 3 direct burial/underground, sunlight/UV resistant 16 gauge 2-conductor/standard wire.