Chamberlain 600A Garage Door Opener User Manual


 
©2004, Chamberlain GmbH
114A2910B-GB All rights reserved
GARAGE DOOR OPENER WARRANTY
Chamberlain GmbH warrants to the first retail purchaser of this product
that the product shall be free from any defect in materials and/or
workmanship for a period of 24 full months (2 years) from the date of
purchase.The motor is warrantied to be free from defects in materials
and/or workmanship for a period of:ML1000A, 60 full months (5 years);
ML800A, 48 full months (4 years);ML600A, 36 full months (3 years) from
the date of purchase.Upon receipt of the product, the first retail
purchaser is under obligation to check the product for any visible defects.
Conditions: The warranty is strictly limited to the reparation or
replacement of the parts of this product which are found to be defective
and does not cover the costs or risks of transportation of the defective
parts or product.
This warranty does not cover non-defect damage caused by
unreasonable use (including use not in complete accordance with
Chamberlain’s instructions for installation, operation and care; failure to
provide necessary maintenance and adjustment; or any adaptations of or
alterations to the products), labor charges for dismantling or reinstalling
of a repaired or replaced unit or replacement batteries.
A product under warranty which is determined to be defective in
materials and/or workmanship will be repaired or replaced (at
Chamberlain's option) at no cost to the owner for the repair and/or
replacement parts and/or product. Defective parts will be repaired or
replaced with new or factory rebuilt parts at Chamberlain's option.
If, during the warranty period, the product appears as though it may be
defective, contact your original place of purchase.
This warranty does not affect the purchaser’s statutory rights under
applicable national legislation in force nor the purchaser’s rights against
the retailer arising from their sales/purchase contract. In the absence of
applicable national or EU legislation, this warranty will be the purchaser’s
sole and exclusive remedy, and neither Chamberlain nor its affiliates or
distributors shall be liable for any incidental or consequential damages for
any express or implied warranty relating to this product.
No representative or person is authorized to assume for Chamberlain
any other liability in connection with the sale of this product.
Declaration of Conformity
The undersigned, hereby declare that the equipment specified, and
all accessories, conforms to the Directives and Standards stated.
Model: . . . . . . . . . . . . . . . . . . . . . .LM600A, LM800A, LM1000A
89/336/EEC
73/23/EEC
1999/5/EC
EN55014-1 (2000), EN55014-2 (1997), EN61000-3-2 (2000),
EN61000-3-3 (1995), EN 301 489-3 (V1.3.1), EN 300 220-3
(V1.1.1), EN60335-1 (1994), and EN60335-2-95 (2000)
Declaration of Incorporation
A power door operator, in combination with a Garage Door must be
installed and maintained according to all the Manufacturers
instructions, to meet the provisions of Machinery Directive,
89/392/EEC.
B. P. Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
May, 2004
Input Voltage...................230-240 VAC, 50Hz
Max. Pull Force...............600N (LM600A), 800N (LM800A),
1000N (LM1000A)
Power..............................6Nm (LM600A), 8Nm (LM800A),
10Nm (LM1000A)
Watts...............................130W (LM600A), 165W
(LM800A), 190W (LM1000A)
Standby Power ...............5.0W (LM600A and LM800A),
5.5W (LM1000A)
Motor
Type................................DC gearmotor permanent
lubrication
Drive Mechanism
Drive ...............................Chain/belt with two-piece trolley
on steel rail.
Length of Travel..............Adjustable to 2,3m (7-1/2 feet)
Travel Rate.....................5"-7" (127-178mm) per second
Lamp...............................On when door starts, off 2-1/2
minutes after stop.
Door Linkage ..................Adjustable door arm. Pull cord
trolley release.
Safety
Personal..........................Push button and automatic
reversal in down direction. Push
button and automatic stop in up
direction.
Electronic........................Automatic force adjustment
Electrical.........................Transformer overload protector
and low voltage push button
wiring.
Limit Device....................Optical RPM/Passpoint detector.
Limit Adjustment .............Electronic, Semi and Fully
Automatic.
Start Circuit.....................Low voltage push button circuit.
Dimensions
Length (Overall)..............3,2m (122-1/2")
Headroom Required .......30mm
Hanging Weight..............32 lb (14,5 kg)
Receiver
Memory Registers ..........16 (LM600A), 32 (LM800A) &
64 (LM1000A)
Operating Frequency......433.92MHz
SPECIAL NOTE: Chamberlain strongly recommends that
the protector system be installed on all garage door
openers.
Your opener can be activated by any of the following
devices:
The Lighted Door Control Button. Hold the button
down until door starts to move.
The Outside Keylock or Keyless Entry System (if you
have installed either of these accessories).
The Remote Control Transmitter. Hold the push button
down until the door starts to move.
Opening the Door Manually: Door should be fully
closed if possible. Weak or broken springs could allow
an open door to fall rapidly. Property damage or
serious personal injury could result.
The door can be opened manually by pulling the release
handle down. To reconnect the door, pull the release
handle down and toward the opener.
Do not use the manual release handle to pull the door
opener or closed. When the Opener is Activated by
Remote Control or Lighted Door Control Button:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop.
3. If opening, the door will stop (allowing space for entry
and exit of pets and for fresh air).
4. If the door has been stopped in a partially open or
closed position, it will reverse direction.
5. If an obstruction is encountered while closing, the door
will reverse.
6. If an obstruction is encountered while opening, the door
will reverse and stop.
7. The optional Protector Systemuses an invisible beam
which, when broken by an obstruction, causes a closing
door to open and prevents an open door from closing. It
is STRONGLY RECOMMENDED for homeowners with
young children.
Allow a 15 minute cooling period after 5 continuous
operations of the opener. The opener light will turn on: 1.
when opener is initially plugged in; 2. when the power is
briefly interrupted; 3. when the opener is activated.
The light turns off automatically after 2-1/2 minutes. Bulb
size is 230V/40W maximum.
OPERATION OF YOUR OPENER SPECIFICATIONS
114A2910B-DK