Vermont Casting MO18 Indoor Fireplace User Manual


 
20012914 7/05 Rev. 0
11
E. Install the Logs F. Adjust the Burner Flame
The burner ame can be adjusted at the manual shutoff
valve beside the replace to obtain the desired ame
appearance.
The flame color will stabilize after ten minutes of
operation.
G. Inspect the Venting System
The replace venting system is designed and constructed to
develop a positive ow adequate to remove ue gases to the
outside atmosphere. See replace installation instructions.
A spillage test must be made before the installed
appliance is left with the consumer
Close all doors and windows in the home.
Light the log set.
After three minutes, test with a smoke match, smoke
candle, stick incense or cigarette one inch below the top of
the opening (lintel) moving across the full width. If spillage
(smoke drawn into the room) occurs, it will most likely be
near the top, outside corners.
Possible Cures if Spilling Occurs
The damper should be fully open.
The replace opening needs to be reduced by adding a
drop panel across the top under the lintel.
The air supply from outdoors needs to be increased. Open
the outside air kit if the appliance is so equipped, or crack
open a door or window.
If necessary, seek expert advice. Do not operate this
appliance.
Cleaning
Periodic examination and cleaning of the venting system
of the replace should be done before initial use and at
least annually by a qualied agency.
Fire Risk
Explosion Risk
Inspect external vent cap regularly.
Ensure no debris blocks cap.
Combustible materials blocking cap may
ignite.
Restricted air flow affects burner
operation.
WARNING
Fire Risk
Explosion Risk
Personal Injury Risk
Failure to position the parts in accordance
with the diagrams provided with the log
packages or failure to use only parts
approved with this appliance may result in
property damage or personal injury.
WARNING
Install the logs using the installation instructions included
with them.
Light the burner as outlined in the operating section. Allow
the ame pattern to stabilize. If you are satised with the
ame pattern go to the next step. If you want more or less
ame around the front log, turn off the gas and move the
burner pan backward or forward.
Once you are satised, turn on the gas and go on to the
next step.
Arrange the top logs as shown in your log set up
instructions. Light the burner as outlined in the operating
instructions and allow the ame to stabilize.
Spread the lava rock around the outside of the burner
pan on the oor of the replace. If possible, cover the gas
connector with the cinders.
MO18 MO24
Step 1
Step 3
Step 2Step 2
Step 1
Step 3