Vermont Casting 3349 Fan User Manual


 
19
Radiance Natural Vent Gas Heater
20004409
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed
by a qualified service agency in accordance with
the manufacturer’s instructions and all applicable
codes and requirements of the authority having
jurisdiction. If the information in these instruc-
tions is not followed exactly, a fire, explosion or
production of carbon monoxide may result
causing property damage, personal injury or loss
of life. The qualified service agency is respon-
sible for the proper installation of this kit. The
installation is not proper and complete until the
operation of the converted appliance is checked
as specified in the manufacturer’s instructions
supplied with the kit.
CAUTION: The gas supply shall be shut off prior
to disconnecting the electrical power, before
proceeding with the conversion.
PILOT
O
N
O
F
F
PILOT
ADJ
L
O
H
I
Main
Gas Line
Gas Supply Inlet
ST226
Fig. 37 Attach the gas line to the left side of the valve.
Conversion Precautions
This conversion must only be completed by qualified
personnel. Before proceeding, turn control knob on
valve to OFF and turn gas supply OFF. Turn OFF any
electricity that may be going to the appliance.
Caution: Allow stove to cool completely before begin-
ning conversion.
Conversion Procedure
1. Remove stove front. Lift stove front up and then
swing bottom out and away to disengage from the
stove body. (Page 22, Fig. 44)
2. Undo the right and left latches at the top of the glass
frame. (Page 22, Fig. 45)
3. Pull the top edge of the glass and frame assembly
away from the firebox face. Place the assembly out
of the way on a flat, padded surface such as a
counter protected by a towel.
4. Remove the logset from the firebox.
5. Remove the rear log bracket by unfastening the
screw and pulling the bracket away. (Fig. 38)
6. Remove the right and left log bracket assembly by
unfastening the two screws which hold the burner in
place. (Fig. 38)
Remove Screws
Rear Log Bracket
Pilot
Left & Right Log
Bracket Assembly
ST350
Fig. 38 Remove rear log bracket and left and right log bracket
assembly.
7. Hold the burner at the right hand side and lift to clear
the right burner leg. Then pull to the right to clear the
injectors on the left hand side.
8. Remove injector orifices from left burner leg using
1/2” wrench. (Fig. 39)
9. Install conversion orifices. (Refer to Table 1)
10. Remove cap from HI/LO knob. This can be accom-
plished by lifting the plastic cap off the screw. (Fig.
40)
11. Remove the screw from center of HI/LO knob with
small screwdriver turning counterclockwise. (Fig. 40)
Fig. 39 Remove and replace injector orifices.
90¡
Left Burner Leg
Injector Orifices
ST353a
L
O
H
I
L
O
H
I
Cap
Hi-Lo
Knob
Lift Open
Center Screw
CO100