BURNER:
The burner is factory set for maximum performance. Should further adjustments be
required loosen slotted hex screw on side of venturi and rotate air shutter until flame
with soft blue inner core is obtained.
BURNER REMOVAL:
The burner can be removed with the unit standing in operating position. Turn off the
gas flow to the unit. Allow the burner to cool off. Remove the wing nut holding the
burner to the frame. Pull down the free burner end, enough to clear the threaded stud
and pull the burner horizontally away from the manifold orifice. The burner can now be
cleaned or replaced. To reinstall, reverse the above procedure.
BURNER MAITENANCE:
The burner should be cleaned both inside the venturi portion and on the outside using a
soft bristle brush. The burner must be replaced into the same position as prior to
removal. Once a year, a qualified service agency should be contacted to inspect the
appliance for safe and proper operation.
Hex Screw
Air Shutter