Carrier Z6 Heating System User Manual


 
46
Table 13 — Electrical Data, 48ZG,ZN070 Units
LEGEND NOTE: Units use 2 (low heat) or 3 (high heat) combustion fan
motors rated at 0.3 FLA each.
NOMINAL
VOLTAGE
(3 Ph 60 Hz)
VOLTAGE
RANGE
COMPR
NO. 1
COMPR
NO. 2
OFM IFM
BASE UNIT
ONLY
EXHAUST
FAN
BASE UNIT WITH
EXHAUST FAN
RLA LRA RLA LRA
Total
FLA
Hp FLA MCA MOCP
Total
Hp
Total
FLA
MCA MOCP
208/230 187-254 108 506 142 690 33.0
15 46.2/42 364.8/360.6 500/500
10 34/30 398.2/390.6 500/500
15 48/44 413.2/404.6 500/500
20 62/56 426.4/416.6 500/500
20 59.4/54 378.0/372.6 500/500
10 34/30 411.4/402.6 500/500
15 48/44 426.4/416.6 500/500
20 62/56 439.6/428.6 500/500
25 74.8/68 393.4/386.6 500/500
10 34/30 426.8/416.6 500/500
15 48/44 441.8/430.6 500/500
20 62/56 455.0/442.6 500/500
30 88.0/80 406.6/389.6 500/500
10 34/30 440.0/428.6 500/500
15 48/44 455.0/442.6 500/500
20 62/56 468.2/454.6 600/500
40 114.4/104.0 433.0/422.6 500/500
10 34/30 466.4/453.0 600/500
15 48/44 481.4/466.6 600/600
20 62/56 494.1/478.6 600/600
460 414-508 50.6 253 65.4 345 16.5
15 21.0 169.9 225
10 15.2 185.1 250
15 22.0 191.9 250
20 28.0 197.9 250
20 27.0 175.9 225
10 15.2 191.1 250
15 22.0 197.9 250
20 28.0 203.9 250
25 34.0 182.9 225
10 15.2 198.1 250
15 22.0 204.9 250
20 28.0 210.9 275
30 40.0 188.9 250
10 15.2 204.1 250
15 22.0 210.9 275
20 28.0 216.9 275
40 52.0 200.9 250
10 15.2 216.1 250
15 22.0 222.9 250
20 28.0 228.9 250
575 518-632 39.1 176 52.6 276 12.0
15 17.0 133.9 175
10 12.2 146.1 175
15 18.0 151.9 200
20 22.0 155.9 200
20 22.0 138.9 175
10 12.2 151.1 200
15 18.0 156.9 200
20 22.0 160.9 200
25 27.0 143.9 175
10 12.2 156.1 200
15 18.0 161.9 200
20 22.0 165.9 200
30 32.0 148.9 200
10 12.2 161.1 200
15 18.0 166.9 200
20 22.0 170.9 200
40 41.0 157.9 200
10 12.2 170.1 200
15 18.0 175.9 225
20 22.0 179.9 225
FLA Full Load Amps
Hp Nominal Horsepower
IFM Indoor (Supply) Fan Motor
LRA Locked Rotor Amps
MCA Minimum Circuit Amps (for wire sizing)
MOCP — Maximum Overcurrent Protection
OFM Outdoor (Condenser) Fan Motor
RLA Rated Load Amps