Carrier
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
30
50YCS036 / 38WQS036 With GAH036
Performance capacities shown in thousands of Btuh.
WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F
EWT °FGPM
PSI FT
CFM
HC KW HE LAT COP HWC TC SC KW HR EER HWC
4.5 1.6 3.8 975
1200 Operation not recommended
20 7.0 3.3 7.6 975 Operation not recommended
1200
9.0 4.9 11.2 975 23.1 2.15 15.7 91.9 3.14 3.2
1200 22.9 2.23 15.3 87.7 3.01 2.7
4.5 1.6 3.7 975 25.6 2.38 17.5 94.3 3.14 3.6 41.8 27.1 1.32 46.3 31.6 1.2
1200 25.9 2.30 18.1 90.0 3.30 3.0 42.2 29.1 1.38 46.9 30.5 1.1
30 7.0 3.2 7.3 975 26.2 2.31 18.3 94.9 3.32 3.7 41.7 27.3 1.27 46.1 32.9 1.3
1200 26.3 2.31 18.4 90.3 3.33 3.2 42.0 29.4 1.33 46.5 31.7 1.1
9.0 4.7 10.9 975 26.8 2.24 19.2 95.5 3.51 3.9 41.6 27.5 1.22 45.8 34.2 1.3
1200 26.6 2.32 18.7 90.5 3.36 3.3 41.9 29.8 1.27 46.2 32.9 1.2
4.5 1.5 3.5 975 29.2 2.46 20.8 97.7 3.48 4.2 40.4 26.5 1.53 45.6 26.5 2.2
1200 29.6 2.37 21.5 92.8 3.65 3.6 40.7 28.5 1.60 46.1 25.5 2.1
40 7.0 3.1 7.1 975 29.8 2.42 21.6 98.3 3.61 4.4 40.4 26.7 1.47 45.4 27.5 2.1
1200 29.9 2.39 21.8 93.1 3.67 3.7 40.6 28.8 1.54 45.9 26.4 2.0
9.0 4.6 10.6 975 30.4 2.38 22.3 98.9 3.75 4.5 40.4 26.9 1.41 45.2 28.5 1.9
1200 30.3 2.41 22.1 93.4 3.69 3.9 40.6 29.0 1.48 45.6 27.5 1.9
4.5 1.5 3.4 975 32.8 2.53 24.2 101.1 3.80 4.8 38.9 26.0 1.73 44.8 22.5 3.2
1200 33.2 2.44 24.9 95.6 3.99 4.2 39.2 27.9 1.81 45.4 21.7 3.1
50 7.0 3.0 6.9 975 33.4 2.53 24.8 101.7 3.88 5.0 39.0 26.1 1.67 44.7 23.4 2.8
1200 33.6 2.47 25.2 95.9 3.99 4.3 39.3 28.1 1.75 45.2 22.5 2.8
9.0 4.4 10.2 975 34.1 2.52 25.5 102.3 3.96 5.2 39.1 26.2 1.61 44.6 24.3 2.4
1200 34.0 2.49 25.5 96.2 4.00 4.5 39.3 28.3 1.68 45.0 23.4 2.6
4.5 1.4 3.3 975 36.2 2.65 27.2 104.4 4.01 5.5 36.9 25.7 1.90 43.3 19.4 3.9
1200 36.9 2.54 28.2 98.4 4.25 4.7 37.4 28.2 1.98 44.1 18.9 3.9
60 7.0 2.9 6.7 975 36.9 2.65 27.9 105.1 4.08 5.6 37.3 25.9 1.84 43.6 20.3 3.6
1200 37.5 2.57 28.7 98.9 4.28 4.9 37.8 28.2 1.91 44.3 19.8 3.6
9.0 4.3 9.9 975 37.7 2.66 28.6 105.8 4.15 5.8 37.7 26.2 1.78 43.8 21.2 3.2
1200 38.2 2.59 29.3 99.4 4.32 5.1 38.2 28.3 1.85 44.5 20.7 3.3
4.5 1.4 3.2 975 39.6 2.76 30.2 107.6 4.20 6.1 34.8 25.4 2.07 41.9 16.8 4.7
1200 40.5 2.64 31.5 101.3 4.49 5.3 35.5 28.4 2.15 42.8 16.5 4.7
70 7.0 2.8 6.5 975 40.5 2.78 31.0 108.4 4.26 6.3 35.6 25.8 2.01 42.4 17.7 4.3
1200 41.4 2.67 32.3 101.9 4.55 5.5 36.3 28.3 2.08 43.4 17.5 4.4
9.0 4.1 9.6 975 41.3 2.80 31.7 109.2 4.32 6.5 36.3 26.2 1.96 43.0 18.6 3.9
1200 42.3 2.69 33.1 102.6 4.61 5.7 37.1 28.2 2.01 44.0 18.5 4.1
4.5 1.3 3.1 975 43.2 2.86 33.4 111.0 4.42 6.8 33.5 24.5 2.30 41.4 14.6 5.4
1200 44.2 2.74 34.8 104.1 4.72 5.8 34.2 27.4 2.39 42.3 14.3 5.5
80 7.0 2.7 6.2 975 44.0 2.88 34.2 111.8 4.47 7.0 34.3 24.9 2.23 41.9 15.4 5.0
1200 45.0 2.76 35.6 104.7 4.78 6.1 35.0 27.3 2.31 42.9 15.2 5.1
9.0 4.0 9.3 975 44.8 2.90 34.9 112.6 4.53 7.3 35.0 25.2 2.17 42.4 16.1 4.6
1200 45.9 2.79 36.4 105.4 4.83 6.3 35.8 27.2 2.23 43.4 16.0 4.8
4.5 1.3 3.0 975 46.7 2.97 36.6 114.4 4.61 7.5 32.3 23.6 2.52 40.9 12.8 6.1
1200 47.8 2.84 38.1 106.9 4.93 6.3 32.9 26.4 2.62 41.9 12.6 6.3
90 7.0 2.6 6.0 975 47.5 2.98 37.4 115.1 4.67 7.8 33.0 24.0 2.45 41.4 13.4 5.7
1200 48.7 2.86 38.9 107.5 4.98 6.6 33.7 26.3 2.54 42.3 13.3 5.9
9.0 3.9 8.9 975 48.3 3.00 38.1 115.9 4.72 8.1 33.7 24.3 2.38 41.8 14.1 5.4
1200 49.5 2.88 39.7 108.2 5.04 6.9 34.4 26.2 2.45 42.8 14.0 5.5
4.5 1.3 2.9 975 30.3 23.7 2.83 39.9 10.7 6.9
1200 30.9 26.5 2.94 40.9 10.5 7.2
100 7.0 2.5 5.8 975 30.9 24.1 2.75 40.3 11.2 6.5
1200 31.6 26.4 2.85 41.3 11.1 6.7
9.0 3.7 8.6 975 31.6 24.4 2.67 40.7 11.8 6.1
1200 Operation not recommended 32.3 26.3 2.75 41.6 11.7 6.2
4.5 1.2 2.8 975 28.2 23.9 3.14 38.9 9.0 7.7
1200 28.8 26.7 3.26 39.9 8.8 8.0
110 7.0 2.4 5.6 975 28.9 24.2 3.05 39.3 9.5 7.2
1200 29.5 26.6 3.16 40.2 9.3 7.5
9.0 3.6 8.3 975 29.5 24.6 2.97 39.6 9.9 6.8
1200 30.1 26.5 3.05 40.5 9.9 7.0
Rev: 12/12/03 B
Operation below 40°F EWT is based on 15% antifreeze solution.
See performance correction tables for operating conditions other than those listed above.
Table does not reflect fan or pump power ISO corrections.
Performance capacities shown in thousands of Btuh.
All entering air conditions are 80°F DB and 67°F WB in cooling and 70°F DB in heating.
All performance data is based upon the lower voltage of dual voltage rated units.