Carrier GT-PX Heat Pump User Manual


 
Carrier
Carrier Indoor & Outdoor Split Geothermal Heat Pumps - Rev.: 08/10/05
28
50YCS024 / 38WQS024 With GAH024
Performance capacities shown in thousands of Btuh.
WPD HEATING - EAT 70°F COOLING - EAT 80/67 °F
EWT °F GPM
PSI FT
CFM
HC KW HE LAT COP HWC TC SC KW HR EER HWC
3.0 0.4 1.0 650
800 Operation not recommended
20 4.5 1.0 2.2 650 Operation not recommended
800
6.0 1.7 3.9 650 16.0 1.62 10.5 92.8 2.89 2.1
800 16.2 1.59 10.8 88.7 2.99 1.8
3.0 0.4 0.9 650 18.9 1.69 13.2 97.0 3.29 2.4 29.4 19.3 0.92 32.6 32.1 0.9
800 19.2 1.62 13.7 92.3 3.48 2.0 31.0 21.2 0.94 34.2 33.0 0.8
30 4.5 0.9 2.1 650 19.1 1.69 13.4 97.2 3.32 2.5 30.0 19.6 0.89 33.0 33.8 1.0
800 19.4 1.64 13.8 92.4 3.47 2.1 31.0 21.2 0.91 34.1 34.3 0.8
6.0 1.6 3.8 650 19.3 1.69 13.5 97.5 3.35 2.6 30.6 19.9 0.86 33.5 35.6 1.0
800 19.5 1.65 13.9 92.6 3.47 2.2 31.1 21.2 0.87 34.1 35.6 0.8
3.0 0.4 0.9 650 21.5 1.75 15.6 100.7 3.60 2.8 28.7 18.7 1.10 32.4 26.2 1.6
800 21.9 1.69 16.1 95.3 3.80 2.4 30.2 20.6 1.12 34.0 26.9 1.4
40 4.5 0.9 2.1 650 21.9 1.77 15.9 101.2 3.63 2.9 29.2 19.0 1.06 32.8 27.6 1.5
800 22.2 1.70 16.3 95.6 3.81 2.5 30.2 20.6 1.08 33.9 28.0 1.4
6.0 1.6 3.7 650 22.3 1.78 16.2 101.8 3.67 3.0 29.7 19.3 1.02 33.1 29.1 1.3
800 22.5 1.72 16.6 96.0 3.82 2.6 30.2 20.6 1.04 33.8 29.2 1.3
3.0 0.4 0.9 650 24.1 1.82 17.9 104.4 3.88 3.2 27.9 18.2 1.28 32.3 21.9 2.2
800 24.5 1.75 18.5 98.3 4.10 2.8 29.4 20.0 1.31 33.8 22.5 2.1
50 4.5 0.9 2.0 650 24.7 1.85 18.4 105.2 3.92 3.3 28.4 18.4 1.23 32.5 23.1 2.0
800 24.9 1.77 18.9 98.9 4.13 2.9 29.3 20.0 1.25 33.6 23.4 2.0
6.0 1.6 3.6 650 25.3 1.87 18.9 106.1 3.96 3.4 28.8 18.7 1.18 32.8 24.4 1.7
800 25.4 1.79 19.3 99.4 4.16 3.0 29.3 20.0 1.20 33.4 24.4 1.8
3.0 0.4 0.9 650 26.6 1.90 20.1 107.9 4.09 3.6 27.0 18.0 1.42 31.9 19.0 2.7
800 27.1 1.82 20.9 101.4 4.38 3.2 28.4 19.6 1.46 33.4 19.5 2.7
60 4.5 0.8 1.9 650 27.5 1.93 20.9 109.1 4.16 3.8 27.2 18.1 1.36 31.9 20.0 2.4
800 27.9 1.84 21.6 102.3 4.43 3.3 28.2 19.6 1.39 32.9 20.3 2.5
6.0 1.5 3.5 650 28.4 1.96 21.7 110.4 4.23 3.9 27.4 18.3 1.30 31.9 21.2 2.2
800 28.7 1.87 22.3 103.2 4.49 3.4 28.0 19.7 1.32 32.5 21.2 2.3
3.0 0.4 0.8 650 29.0 1.98 22.3 111.3 4.29 4.1 26.1 17.8 1.57 31.5 16.7 3.2
800 29.7 1.88 23.3 104.4 4.63 3.5 27.5 19.3 1.61 33.0 17.1 3.2
70 4.5 0.8 1.9 650 30.2 2.02 23.3 113.0 4.38 4.2 26.1 17.9 1.49 31.2 17.5 2.9
800 30.8 1.92 24.3 105.7 4.72 3.7 27.0 19.3 1.53 32.3 17.7 3.0
6.0 1.5 3.4 650 31.4 2.06 24.4 114.7 4.47 4.3 26.1 18.0 1.41 30.9 18.4 2.7
800 32.0 1.95 25.3 107.0 4.80 3.8 26.6 19.4 1.44 31.5 18.4 2.8
3.0 0.3 0.8 650 31.6 2.05 24.6 115.0 4.51 4.5 25.4 17.1 1.77 31.5 14.4 3.6
800 32.4 1.95 25.7 107.4 4.87 3.9 26.8 18.5 1.81 32.9 14.8 3.7
80 4.5 0.8 1.8 650 32.9 2.09 25.8 116.9 4.60 4.7 25.4 17.2 1.68 31.1 15.1 3.4
800 33.6 1.99 26.8 108.9 4.96 4.0 26.3 18.6 1.72 32.2 15.3 3.5
6.0 1.4 3.2 650 34.3 2.14 27.0 118.8 4.69 4.8 25.4 17.2 1.59 30.8 16.0 3.1
800 34.9 2.03 28.0 110.4 5.04 4.2 25.9 18.6 1.62 31.4 15.9 3.2
3.0 0.3 0.8 650 34.2 2.12 26.9 118.6 4.72 5.0 24.7 16.4 1.96 31.4 12.6 4.1
800 35.0 2.01 28.1 110.5 5.10 4.2 26.0 17.7 2.01 32.9 12.9 4.3
90 4.5 0.8 1.7 650 35.6 2.17 28.2 120.8 4.81 5.2 24.7 16.4 1.86 31.1 13.3 3.9
800 36.4 2.06 29.4 112.1 5.18 4.4 25.6 17.8 1.91 32.1 13.4 4.0
6.0 1.4 3.1 650 37.1 2.22 29.5 122.9 4.89 5.4 24.7 16.5 1.77 30.7 14.0 3.6
800 37.8 2.11 30.6 113.8 5.25 4.6 25.2 17.9 1.80 31.3 14.0 3.7
3.0 0.3 0.7 650 23.4 15.9 2.20 30.9 10.6 4.6
800 24.6 17.2 2.26 32.3 10.9 4.8
100 4.5 0.7 1.7 650 23.3 16.0 2.09 30.5 11.2 4.4
800 24.2 17.3 2.14 31.5 11.3 4.5
6.0 1.3 3.0 650 23.3 16.0 1.98 30.1 11.8 4.1
800 Operation not recommended 23.8 17.3 2.02 30.7 11.8 4.2
3.0 0.3 0.7 650 22.0 15.4 2.44 30.3 9.0 5.1
800 23.2 16.7 2.50 31.7 9.3 5.3
110 4.5 0.7 1.6 650 22.0 15.5 2.32 29.9 9.5 4.8
800 22.8 16.7 2.37 30.9 9.6 5.0
6.0 1.3 2.9 650 21.9 15.5 2.20 29.4 10.0 4.6
800 22.4 16.8 2.24 30.0 10.0 4.7
Rev: 12/12/03 B
Operation below 40°F EWT is based on 15% antifreeze solution.
See performance correction tables for operating conditions other than those listed above.
Table does not reflect fan or pump power ISO corrections.
Interpolation is permissable, extrapolation is not.
All entering air conditions are 80°F DB and 67°F WB in cooling and 70°F DB in heating.
All performance data is based upon the lower voltage of dual voltage rated units.